c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
2,047 kWh
719 cooling + 1,328 heating
Estimated running cost
$655 / year
$55 / month Β· $6,550 over 10 years
Capacity
9.5 kW cooling
11.2 kW heating

8% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 73% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-100PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,967$1,269$12,694
Mixed zone 2,047$655$6,550
Hot zone 2,216$709$7,091

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNA1E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Panasonic U-100PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU100WR2 U30/UTN100MA NA010.8 kW heating9.5 kW cooling2,807 kWh/yr2.5$898
Mitsubishi Heavy Industries SRC95ZRA-W / SRK95ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr3.5$657
Daikin RXM95WVMA / FTXM95WVMA10.3 kW heating9.5 kW cooling2,352 kWh/yr3$753
Fujitsu AOTH34KMTD/ASTH34KMTD10.3 kW heating9.5 kW cooling2,129 kWh/yr3.5$681
Mitsubishi Heavy Industries DXC33ZRA-W / DXK33ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr3.5$657
Fujitsu AOTH34KNTA/ASTH34KNTA10.3 kW heating9.5 kW cooling2,129 kWh/yr3.5$681
LG UU100WR3 U30/UTN100MA NA010.8 kW heating9.5 kW cooling2,242 kWh/yr3$717
Daikin RXM95P2VMA / FTXM95P2VMA10.3 kW heating9.4 kW cooling2,477 kWh/yr2.5$793

Compare U-100PZH3R5/S-1014PT3E with another model

Panasonic U-100PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
–
EER, full load (tested)
4.46
COP, full load (tested)
4.40
Rated AEER
4.05
Rated ACOP
4.00
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8861,093
Coldresidential3.52.54623,505
Mixedcommercial––1,141576
Mixedresidential3.53.07191,328
Hotcommercial––2,573138
Hotresidential4.54.02,006210
Part-load test points (22 values)
h__h1_min_cap_power_rated
525 W
h__h2_ext_cap_power_rated
4600 W
c__t1_half_cap_power_rated
830 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1010 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3100 W
h__h2_ext_cap_heat_cap_rated
12500 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
415 W
c__low_temp_half_cap_power_rated
660 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3500 W
c__low_temp_half_cap_cooling_cap_rated
5000 W

Australian GEMS registration details

Registration number
AAC9782
GEMS registration id
–
Status
approved
Registration expires
7 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.