c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
2,047 kWh
719 cooling + 1,328 heating
Estimated running cost
$655 / year
$55 / month Β· $6,550 over 10 years
Capacity
9.5 kW cooling
11.2 kW heating

8% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 73% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-100PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,967$1,269$12,694
Mixed zone 2,047$655$6,550
Hot zone 2,216$709$7,091

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling1,750 kWh/yr4$560
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling1,757 kWh/yr3.5$562

Air conditioners similar to the Panasonic U-100PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU100WR2 U30/UTN100MA NA010.8 kW heating9.5 kW cooling2,807 kWh/yr2.5$898
Mitsubishi Heavy Industries SRC95ZRA-W / SRK95ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr3.5$657
Daikin RXM95WVMA / FTXM95WVMA10.3 kW heating9.5 kW cooling2,352 kWh/yr3$753
Fujitsu AOTH34KMTD/ASTH34KMTD10.3 kW heating9.5 kW cooling2,129 kWh/yr3.5$681
Mitsubishi Heavy Industries DXC33ZRA-W / DXK33ZRA-WF110.3 kW heating9.5 kW cooling2,054 kWh/yr3.5$657
Fujitsu AOTH34KNTA/ASTH34KNTA10.3 kW heating9.5 kW cooling2,129 kWh/yr3.5$681
LG UU100WR3 U30/UTN100MA NA010.8 kW heating9.5 kW cooling2,242 kWh/yr3$717
Daikin RXM95P2VMA / FTXM95P2VMA10.3 kW heating9.4 kW cooling2,477 kWh/yr2.5$793

Compare U-100PZH3R8/S-1014PT3E with another model

Panasonic U-100PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
2.29 kW
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
2.74 kW
EER, full load (tested)
4.46
COP, full load (tested)
4.40
Rated AEER
4.05
Rated ACOP
4.00
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1590 Γ— 235 Γ— 690 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8861,093
Coldresidential3.52.54623,505
Mixedcommercial––1,141576
Mixedresidential3.53.07191,328
Hotcommercial––2,573138
Hotresidential4.54.02,006210
Part-load test points (22 values)
h__h1_min_cap_power_rated
525 W
h__h2_ext_cap_power_rated
4600 W
c__t1_half_cap_power_rated
830 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1010 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3100 W
h__h2_ext_cap_heat_cap_rated
12500 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
415 W
c__low_temp_half_cap_power_rated
660 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3500 W
c__low_temp_half_cap_cooling_cap_rated
5000 W

Australian GEMS registration details

Registration number
AAC9783
GEMS registration id
175925
Status
approved, available (self-reported)
Registration expires
11 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.