Panasonic U-180PE2R8A/S-180PE3R5B is a 18 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8055).
- Energy rating (cooling)
- 1.5
- Heating: 1.5
- Annual electricity use
- 5,376 kWh
- 2,159 cooling + 3,217 heating
- Estimated running cost
- $1,720 / year
- $143 / month Β· $17,203 over 10 years
- Capacity
- 18 kW cooling
- 20 kW heating
23% more electricity than the median of 53 comparable 18 kW reverse cycle ducted split system registrations (4,376 kWh a year) in the mixed zone. Uses less than 17% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 16% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-180PE2R8A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 10,072 | $3,223 | $32,230 |
| Mixed zone | 5,376 | $1,720 | $17,203 |
| Hot zone | 6,748 | $2,159 | $21,594 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 18 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling1,784 kWh/yr | 2 | $571 | |
| AirSmart IES-***15.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr | 3.5 | $1,075 | |
| Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling3,556 kWh/yr | 3.5 | $1,138 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling3,585 kWh/yr | 3.5 | $1,147 |
Air conditioners similar to the Panasonic U-180PE2R8A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric PUZ-ZM180YKA-A / PEA-M180LAA20 kW heating18 kW cooling4,426 kWh/yr | 2.5 | $1,416 | |
| Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling4,128 kWh/yr | 2.5 | $1,321 | |
| Tosot TFH65DEXL-S6DND7D/O / TFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling4,234 kWh/yr | 3 | $1,355 | |
| Gree GFH65DEXL-S6DND7D/O / GFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling4,234 kWh/yr | 3 | $1,355 | |
| Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling4,153 kWh/yr | 2.5 | $1,329 | |
| Reclaim Energy CA-D180D1HWH-ODU/CA-D180D1HWH-IDU20 kW heating18 kW cooling4,376 kWh/yr | 3 | $1,400 | |
| TCL TCD180D1HWHS2-DVO/TCD180D1HWHS2-DVI20 kW heating18 kW cooling4,376 kWh/yr | 3 | $1,400 | |
| Braemar KCHB180D1B/KDHB180D1S19.5 kW heating18 kW cooling4,234 kWh/yr | 3 | $1,355 |
Compare U-180PE2R8A/S-180PE3R5B with another model
Panasonic U-180PE2R8A specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 18.00 kW
- Cooling power input
- 5.96 kW
- Rated heating capacity (7 Β°C)
- 20.00 kW
- Heating power input
- 5.66 kW
- EER, full load (tested)
- 3.09
- COP, full load (tested)
- 3.49
- Rated AEER
- 2.98
- Rated ACOP
- 3.48
- Standby power (PIA)
- 25.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1456 Γ 486 Γ 916 mm
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-180PE2R8A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 3,092 | 2,790 |
| Coldresidential | residential | 1.5 | 1.5 | 1,400 | 8,672 |
| Mixedcommercial | commercial | β | β | 3,859 | 1,462 |
| Mixedresidential | residential | 1.5 | 1.5 | 2,159 | 3,217 |
| Hotcommercial | commercial | β | β | 8,421 | 332 |
| Hotresidential | residential | 2.0 | 2.0 | 6,238 | 510 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 6520 W
- c__t1_half_cap_power_rated
- 2630 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 2450 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 16000 W
- h__h1_half_cap_heat_cap_rated
- 10000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 5447.4400000000005 W
- c__low_temp_half_cap_power_rated
- 2403.82 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 9500 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 19386 W
- c__low_temp_half_cap_cooling_cap_rated
- 10231.5 W
Australian GEMS registration details
- Registration number
- AAC8055
- GEMS registration id
- 159443
- Status
- approved, available (self-reported)
- Registration expires
- 13 February 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.