c/kWh
Energy rating (cooling)
2
Heating: 2.5
Annual electricity use
4,519 kWh
1,911 cooling + 2,608 heating
Estimated running cost
$1,446 / year
$121 / month Β· $14,461 over 10 years
Capacity
18 kW cooling
20 kW heating

3% more electricity than the median of 52 comparable 18 kW reverse cycle ducted split system registrations (4,376 kWh a year) in the mixed zone. Uses less than 37% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 20% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-180PZH2R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,273$2,647$26,474
Mixed zone 4,519$1,446$14,461
Hot zone 5,939$1,900$19,005

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 18 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling1,784 kWh/yr2$571
AirSmart IES-700-AC15.8 kW heating17 kW cooling3,358 kWh/yr3.5$1,075
AirSmart IES-70015.8 kW heating17 kW cooling3,358 kWh/yr3.5$1,075
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling3,556 kWh/yr3.5$1,138
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling3,585 kWh/yr3.5$1,147

Air conditioners similar to the Panasonic U-180PZH2R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUZ-ZM180YKA-A / PEA-M180LAA20 kW heating18 kW cooling4,426 kWh/yr2.5$1,416
Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling4,128 kWh/yr2.5$1,321
Tosot TFH65DEXL-S6DND7D/O / TFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling4,234 kWh/yr3$1,355
Gree GFH65DEXL-S6DND7D/O / GFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling4,234 kWh/yr3$1,355
Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling4,153 kWh/yr2.5$1,329
Reclaim Energy CA-D180D1HWH-ODU/CA-D180D1HWH-IDU20 kW heating18 kW cooling4,376 kWh/yr3$1,400
TCL TCD180D1HWHS2-DVO/TCD180D1HWHS2-DVI20 kW heating18 kW cooling4,376 kWh/yr3$1,400
Braemar KCHB180D1B/KDHB180D1S19.5 kW heating18 kW cooling4,234 kWh/yr3$1,355

Compare U-180PZH2R8/S-180PE3R5B with another model

Panasonic U-180PZH2R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
18.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
20.00 kW
Heating power input
–
EER, full load (tested)
3.34
COP, full load (tested)
3.82
Rated AEER
3.15
Rated ACOP
3.69
Standby power (PIA)
25.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-180PZH2R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,6242,190
Coldresidential2.02.01,2357,038
Mixedcommercial––3,2961,137
Mixedresidential2.02.51,9112,608
Hotcommercial––7,412261
Hotresidential2.53.55,539400
Part-load test points (23 values)
h__h1_min_cap_power_rated
1060 W
h__h2_ext_cap_power_rated
6210 W
c__t1_half_cap_power_rated
2200 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2000 W
h__h1_have_min_cap_results
Yes
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
5500 W
h__h2_ext_cap_heat_cap_rated
18000 W
h__h1_half_cap_heat_cap_rated
10100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
1260 W
c__low_temp_full_cap_power_rated
5145.82 W
c__low_temp_half_cap_power_rated
2010.8 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
9100 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
6300 W
c__low_temp_full_cap_cooling_cap_rated
19386 W
c__low_temp_half_cap_cooling_cap_rated
9800.7 W

Australian GEMS registration details

Registration number
AAC8062
GEMS registration id
–
Status
approved
Registration expires
19 February 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.