c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
15,403 kWh
4,675 cooling + 10,728 heating
Estimated running cost
$4,929 / year
$411 / month Β· $49,290 over 10 years
Capacity
56 kW cooling
63 kW heating

33% more electricity than the median of 10 comparable 50 kW reverse cycle ducted registrations (11,594 kWh a year) in the mixed zone. Uses less than 10% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 4% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-20ME2R8E running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 34,255$10,962$109,616
Mixed zone 15,403$4,929$49,290
Hot zone 14,876$4,760$47,603

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 56 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Haier AV18IMAURA56.5 kW heating50 kW cooling5,671 kWh/yr2$1,815
Panasonic U-18ME2R8 / S-22MF2E5A / S-90MF2E5A / S-106MF2E5A56 kW heating50 kW cooling11,792 kWh/yr3.5$3,773
Panasonic U-18ME2R8E / S-22MF2E5A / S-90MF2E5A / S-106MF2E5A56 kW heating50 kW cooling11,792 kWh/yr3.5$3,773

Air conditioners similar to the Panasonic U-20ME2R8E

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier AV20IMAURA58 kW heating56 kW cooling17,055 kWh/yr2$5,458
Haier AV18IMAURA56.5 kW heating50 kW cooling5,671 kWh/yr2$1,815

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-18ME2R8 / S-22MF2E5A / S-90MF2E5A / S-106MF2E5A56 kW heating50 kW cooling11,792 kWh/yr3.5$3,773
Panasonic U-18ME2R8E / S-22MF2E5A / S-90MF2E5A / S-106MF2E5A56 kW heating50 kW cooling11,792 kWh/yr3.5$3,773

Compare U-20ME2R8E with another model

Panasonic U-20ME2R8E specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
56.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
63.00 kW
Heating power input
–
EER, full load (tested)
2.82
COP, full load (tested)
3.47
Rated AEER
2.88
Rated ACOP
3.54
Standby power (PIA)
83.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-20ME2R8E zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,2898,642
Coldresidential3.51.02,90031,355
Mixedcommercial––5,7664,161
Mixedresidential3.01.54,67510,728
Hotcommercial––16,672734
Hotresidential3.54.013,7081,168
Part-load test points (21 values)
c__t1_min_cap_power_rated
880 W
h__h1_min_cap_power_rated
740 W
h__h2_ext_cap_power_rated
14800 W
c__t1_half_cap_power_rated
4850 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
5600 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4280 W
h__h2_ext_cap_heat_cap_rated
38000 W
h__h1_half_cap_heat_cap_rated
31500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
590 W
c__t1_min_cap_cooling_cap_rated
6700 W
c__t1_half_cap_cooling_cap_rated
28000 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
6800 W

Other model numbers on registration AAC9307

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC9307
GEMS registration id
–
Status
approved
Registration expires
24 September 2030
Registered for sale in
Australia, New Zealand
Family
U-20ME2R8
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
21

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.