Reverse cycle multi-split / vrf air conditioner
Panasonic U-4LE2R5E Air Conditioner
Panasonic U-4LE2R5E is a 12.1 kW reverse cycle multi-split / vrf air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC6858).
A newer registration of this model exists: AAC6860.
- Energy rating (cooling)
- 3
- Heating: 4
- Annual electricity use
- 2,261 kWh
- 1,010 cooling + 1,251 heating
- Estimated running cost
- $724 / year
- $60 / month Β· $7,235 over 10 years
- Capacity
- 12.1 kW cooling
- 12.5 kW heating
20% less electricity than the median of 18 comparable 12.5 kW reverse cycle multi-split / vrf registrations (2,835 kWh a year) in the mixed zone. Uses less than 72% of them.
Across all 3,681 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-4LE2R5E running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,134 | $1,323 | $13,229 |
| Mixed zone | 2,261 | $724 | $7,235 |
| Hot zone | 2,979 | $953 | $9,533 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling2,157 kWh/yr | 3 | $690 |
Air conditioners similar to the Panasonic U-4LE2R5E
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar MCMX120D107B14 kW heating12.1 kW cooling3,786 kWh/yr | 1.5 | $1,212 | |
| Rinnai MON5H11B12.5 kW heating12 kW cooling2,675 kWh/yr | 3.5 | $856 | |
| LG FM120AH12.9 kW heating12.3 kW cooling2,735 kWh/yr | 3 | $875 | |
| Mitsubishi Electric PUMY-SP112YKMD3-A-BS14 kW heating12.5 kW cooling2,935 kWh/yr | 2.5 | $939 | |
| Mitsubishi Electric PUMY-SP112VKMD3-A14 kW heating12.5 kW cooling2,935 kWh/yr | 2.5 | $939 | |
| Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling2,157 kWh/yr | 3 | $690 |
Other Panasonic models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-4LE2R812.5 kW heating12.1 kW cooling2,234 kWh/yr | 3 | $715 | |
| Panasonic U-4LE2R8E12.5 kW heating12.1 kW cooling2,234 kWh/yr | 3 | $715 |
Compare U-4LE2R5E with another model
Panasonic U-4LE2R5E specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 12.10 kW
- Cooling power input
- 2.69 kW
- Rated heating capacity (7 Β°C)
- 12.50 kW
- Heating power input
- 2.41 kW
- EER, full load (tested)
- 4.40
- COP, full load (tested)
- 5.18
- Rated AEER
- 4.31
- Rated ACOP
- 4.95
- Standby power (PIA)
- 34.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 69 dB(A)
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-4LE2R5E zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,357 | 1,091 |
| Coldresidential | residential | 3.0 | 3.0 | 668 | 3,466 |
| Mixedcommercial | commercial | β | β | 1,684 | 565 |
| Mixedresidential | residential | 3.0 | 4.0 | 1,010 | 1,251 |
| Hotcommercial | commercial | β | β | 3,633 | 162 |
| Hotresidential | residential | 4.0 | 5.0 | 2,744 | 235 |
Part-load test points (18 values)
- c__t1_half_cap_power_rated
- 1030 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 820 W
- h__h1_have_min_cap_results
- No
- h__h2_full_cap_power_rated
- 3160 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_half_cap_heat_cap_rated
- 6300 W
- h__h2_full_cap_heat_cap_rated
- 11000 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_full_cap_power_rated
- 2458.6600000000003 W
- c__low_temp_half_cap_power_rated
- 941.4200000000001 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 6100 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 13031.699999999999 W
- c__low_temp_half_cap_cooling_cap_rated
- 6569.7 W
Related Panasonic model numbers starting with U4LE2R5
2 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.
Other model numbers on registration AAC6858
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC6858
- GEMS registration id
- 148788
- Status
- approved, available (self-reported)
- Registration expires
- 10 August 2027
- Registered for sale in
- Australia, New Zealand
- Family
- U-4LE2R5
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.