c/kWh
Energy rating (cooling)
3
Heating: 4
Annual electricity use
2,238 kWh
1,008 cooling + 1,230 heating
Estimated running cost
$716 / year
$60 / month Β· $7,162 over 10 years
Capacity
12.1 kW cooling
12.5 kW heating

21% less electricity than the median of 18 comparable 12.5 kW reverse cycle multi-split / vrf registrations (2,835 kWh a year) in the mixed zone. Uses less than 83% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-4LZ2E5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,070$1,302$13,024
Mixed zone 2,238$716$7,162
Hot zone 2,969$950$9,501

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling2,157 kWh/yr3$690

Air conditioners similar to the Panasonic U-4LZ2E5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar MCMX120D107B14 kW heating12.1 kW cooling3,786 kWh/yr1.5$1,212
Rinnai MON5H11B12.5 kW heating12 kW cooling2,675 kWh/yr3.5$856
LG FM120AH12.9 kW heating12.3 kW cooling2,735 kWh/yr3$875
Mitsubishi Electric PUMY-SP112YKMD3-A-BS14 kW heating12.5 kW cooling2,935 kWh/yr2.5$939
Mitsubishi Electric PUMY-SP112VKMD3-A-BS14 kW heating12.5 kW cooling2,935 kWh/yr2.5$939
Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling2,157 kWh/yr3$690

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-4LE2R812.5 kW heating12.1 kW cooling2,234 kWh/yr3$715
Panasonic U-4LE2R8E12.5 kW heating12.1 kW cooling2,234 kWh/yr3$715

Compare U-4LZ2E5 with another model

Panasonic U-4LZ2E5 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.10 kW
Cooling power input
2.67 kW
Rated heating capacity (7 Β°C)
12.50 kW
Heating power input
2.37 kW
EER, full load (tested)
4.71
COP, full load (tested)
5.46
Rated AEER
4.34
Rated ACOP
5.03
Standby power (PIA)
34.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-4LZ2E5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3551,075
Coldresidential3.03.06663,404
Mixedcommercial––1,681557
Mixedresidential3.04.01,0081,230
Hotcommercial––3,625161
Hotresidential4.05.52,736233
Part-load test points (18 values)
c__t1_half_cap_power_rated
1030 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
810 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3040 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
6300 W
h__h2_full_cap_heat_cap_rated
11000 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2440.38 W
c__low_temp_half_cap_power_rated
941.4200000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6100 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
13031.699999999999 W
c__low_temp_half_cap_cooling_cap_rated
6569.7 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
U-4LZ2E5AAC1029532,368

Australian GEMS registration details

Registration number
AAC6973
GEMS registration id
148599
Status
approved, available (self-reported)
Registration expires
8 September 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.