c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
1,476 kWh
566 cooling + 910 heating
Estimated running cost
$472 / year
$39 / month Β· $4,723 over 10 years
Capacity
6 kW cooling
6 kW heating

10% more electricity than the median of 104 comparable 6 kW reverse cycle split system registrations (1,340 kWh a year) in the mixed zone. Uses less than 16% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 64% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-60PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,815$901$9,008
Mixed zone 1,476$472$4,723
Hot zone 1,749$560$5,597

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
TCL TAC-VX18HSV/UC5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
TCL TAC-VX18HSV/UA5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
Hyundai HYSSSAC53TB5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327
Hyundai HYSSSAC53TC5.3 kW heating5.3 kW cooling1,022 kWh/yr4$327

Air conditioners similar to the Panasonic U-60PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling1,203 kWh/yr4.5$385
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Daikin RXM60AVMA / FTXM60AVMA7.2 kW heating6 kW cooling1,205 kWh/yr4.5$386
Daikin RXM60WVMA / FTXM60WVMA7.2 kW heating6 kW cooling1,213 kWh/yr4.5$388
Midea MFEP60VB-W/MFEP60VB-N6.6 kW heating6 kW cooling1,203 kWh/yr4.5$385

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling1,101 kWh/yr3.5$352
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling1,092 kWh/yr3.5$349

Compare U-60PZ3R5/S-60PY3E with another model

Panasonic U-60PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
6.00 kW
Cooling power input
1.77 kW
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
1.66 kW
EER, full load (tested)
3.46
COP, full load (tested)
3.69
Rated AEER
3.32
Rated ACOP
3.54
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
840 Γ— 256 Γ— 840 mm
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-60PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––722759
Coldresidential2.51.53642,451
Mixedcommercial––922395
Mixedresidential2.52.0566910
Hotcommercial––2,09993
Hotresidential3.02.51,608141
Part-load test points (20 values)
h__h1_min_cap_power_rated
390 W
c__t1_half_cap_power_rated
650 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
665 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
2100 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1800 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_full_cap_heat_cap_rated
5100 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
310 W
c__low_temp_half_cap_power_rated
550 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2000 W
c__low_temp_half_cap_cooling_cap_rated
3200 W

Australian GEMS registration details

Registration number
AAC10463
GEMS registration id
182220
Status
approved, available (self-reported)
Registration expires
20 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9