c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
1,399 kWh
596 cooling + 803 heating
Estimated running cost
$448 / year
$37 / month Β· $4,477 over 10 years
Capacity
6.8 kW cooling
6.8 kW heating

13% less electricity than the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 99% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-71PZ4R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,606$834$8,339
Mixed zone 1,399$448$4,477
Hot zone 1,819$582$5,821

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 6.8 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling1,092 kWh/yr3.5$349
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling1,101 kWh/yr3.5$352
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling1,203 kWh/yr4.5$385

Air conditioners similar to the Panasonic U-71PZ4R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba RAV-GP801ATP-A/RAV-GM801CTP-A8 kW heating7.1 kW cooling1,559 kWh/yr3.5$499
Samsung Electronics AR24BXGYCWKX/ AR24BXGYCWKN7.2 kW heating6.8 kW cooling1,679 kWh/yr3$537
Samsung Electronics AR70H24CADWX / AR70H24CADWN7.2 kW heating6.8 kW cooling1,590 kWh/yr3$509
LG UU70WR2 U40/UTN70PB NB07.5 kW heating6.8 kW cooling2,132 kWh/yr1.5$682
Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr4.5$439
Daikin RXM71YFVMA / FVXM71YVMA8 kW heating6.7 kW cooling1,704 kWh/yr3$545

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling1,421 kWh/yr2.5$455
Panasonic U-71PZH3R5/S-6071PT3E8 kW heating6.8 kW cooling1,497 kWh/yr3.5$479

Compare U-71PZ4R5 / S-6071PT3E with another model

Panasonic U-71PZ4R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
6.80 kW
Cooling power input
1.88 kW
Rated heating capacity (7 Β°C)
6.80 kW
Heating power input
1.57 kW
EER, full load (tested)
3.83
COP, full load (tested)
4.52
Rated AEER
3.55
Rated ACOP
4.23
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-71PZ4R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––772690
Coldresidential3.02.53822,224
Mixedcommercial––985354
Mixedresidential3.03.0596803
Hotcommercial––2,20686
Hotresidential3.54.01,690129
Part-load test points (22 values)
h__h1_min_cap_power_rated
380 W
h__h2_ext_cap_power_rated
1950 W
c__t1_half_cap_power_rated
670 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
600 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2250 W
h__h2_ext_cap_heat_cap_rated
5850 W
h__h1_half_cap_heat_cap_rated
3400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
420 W
c__low_temp_half_cap_power_rated
560 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2800 W
c__low_temp_half_cap_cooling_cap_rated
3600 W

Australian GEMS registration details

Registration number
AAC9346
GEMS registration id
171987
Status
approved, available (self-reported)
Registration expires
28 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.