c/kWh
Energy rating (cooling)
5
Annual electricity use
221 kWh
Estimated running cost
$71 / year
$6 / month Β· $707 over 10 years
Capacity
3.5 kW cooling

19% less electricity than the median of 23 comparable 3.5 kW cooling only split system registrations (273 kWh a year) in the mixed zone. Uses less than 91% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 99% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Rinnai HONCJ35B1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 137$44$438
Mixed zone 221$71$707
Hot zone 626$200$2,003

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Rinnai HONCJ35B1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRC13YSA-W/SRK13YSA-WF13.5 kW cooling259 kWh/yr4$83
Daikin RKM35YVMA / FTKM35YVMA3.5 kW cooling223 kWh/yr4.5$71
Hitachi RAC-DJ35PCAT/RAK-DJ35PCAT3.5 kW cooling220 kWh/yr5$70
Daikin RKM35W2VMA / FTKM35W2VMA3.5 kW cooling224 kWh/yr4.5$72
Panasonic CU-U35AKR / CS-U35AKR3.5 kW cooling268 kWh/yr3.5$86
Mitsubishi Electric MUY-GW35VFD/MSY-GW35VFD23.5 kW cooling231 kWh/yr4.5$74
Mitsubishi Heavy Industries SRC13YTA-W/SRK13YTA-WF3.5 kW cooling243 kWh/yr4$78
Mitsubishi Electric MUY-GW35VFD2/MSY-GW35VFD2 Series3.5 kW cooling231 kWh/yr4.5$74

Compare HONCJ35B1 / HINCJ35B1 with another model

Rinnai HONCJ35B1 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.50 kW
Cooling power input
0.87 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
4.10
COP, full load (tested)
–
Rated AEER
4.02
Rated ACOP
–
Standby power (PIA)
0.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
49.7 dB(A)
Outdoor sound power
54.1 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai HONCJ35B1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––70–
Coldresidential5.5–137–
Mixedcommercial––222–
Mixedresidential5.0–221–
Hotcommercial––595–
Hotresidential5.5–626–
Part-load test points (9 values)
c__t1_half_cap_power_rated
420 W
c__t1_have_min_cap_results
No
c__low_temp_full_cap_power_rated
795.1800000000001 W
c__low_temp_half_cap_power_rated
230 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
3769.5 W
c__low_temp_half_cap_cooling_cap_rated
1750 W

Australian GEMS registration details

Registration number
AAC8500
GEMS registration id
164828
Status
approved, available (self-reported)
Registration expires
16 October 2029
Registered for sale in
Australia
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.