Australia Β· costs in AUD

Reverse cycle multi-split / vrf air conditioner
Samsung Electronics AM260DXVGGH/SA Air Conditioner
Samsung Electronics AM260DXVGGH/SA is a 72.8 kW reverse cycle multi-split / vrf air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7686).
- Energy rating (cooling)
- 2.5
- Heating: 2
- Annual electricity use
- 18,784 kWh
- 7,031 cooling + 11,753 heating
- Estimated running cost
- $6,011 / year
- $501 / month Β· $60,109 over 10 years
- Capacity
- 72.8 kW cooling
- 78.4 kW heating
14% less electricity than the median of 7 comparable 80 kW and above reverse cycle multi-split / vrf registrations (21,869 kWh a year) in the mixed zone. Uses less than 57% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 3% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Samsung Electronics AM260DXVGGH running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 37,372 | $11,959 | $119,590 |
| Mixed zone | 18,784 | $6,011 | $60,109 |
| Hot zone | 22,665 | $7,253 | $72,528 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 72.8 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38VT024188QTSG64.5 kW heating64.5 kW cooling5,352 kWh/yr | 3.5 | $1,713 | |
| Carrier 38VT024188HTSG69 kW heating67 kW cooling6,173 kWh/yr | 2.5 | $1,975 | |
| Hitachi RAS-24FSNS77.5 kW heating67 kW cooling7,421 kWh/yr | 1.5 | $2,375 | |
| Hitachi RAS-24FSXNS77.5 kW heating67 kW cooling7,421 kWh/yr | 1.5 | $2,375 | |
| LG ARUM241LTE674.3 kW heating67.2 kW cooling15,247 kWh/yr | 3 | $4,879 |
Air conditioners similar to the Samsung Electronics AM260DXVGGH
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG ARUM261LTE674.3 kW heating72.8 kW cooling16,150 kWh/yr | 3 | $5,168 | |
| LG ARUM260LTE574.3 kW heating72.8 kW cooling21,869 kWh/yr | 1.5 | $6,998 | |
| Daikin RQCEQ744PY180.8 kW heating74.4 kW cooling29,405 kWh/yr | 1.5 | $9,410 | |
| Daikin RQCEQ712PY178.4 kW heating71.2 kW cooling27,999 kWh/yr | 1.5 | $8,960 | |
| Carrier 38VT024188HTSG69 kW heating67 kW cooling6,173 kWh/yr | 2.5 | $1,975 | |
| Hitachi RAS-24FSNS77.5 kW heating67 kW cooling7,421 kWh/yr | 1.5 | $2,375 | |
| Hitachi RAS-24FSXNS77.5 kW heating67 kW cooling7,421 kWh/yr | 1.5 | $2,375 |
Other Samsung Electronics models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Samsung Electronics AM260DXVGGR/SA78.4 kW heating72.8 kW cooling18,784 kWh/yr | 2.5 | $6,011 |
Compare AM260DXVGGH/SA with another model
Samsung Electronics AM260DXVGGH specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 72.80 kW
- Cooling power input
- 22.99 kW
- Rated heating capacity (7 Β°C)
- 78.40 kW
- Heating power input
- 20.75 kW
- EER, full load (tested)
- 3.17
- COP, full load (tested)
- 3.78
- Rated AEER
- 3.16
- Rated ACOP
- 3.76
- Standby power (PIA)
- 21.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China, South Korea
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Samsung Electronics AM260DXVGGH zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 9,373 | 10,206 |
| Coldresidential | residential | 3.0 | 1.5 | 4,468 | 32,904 |
| Mixedcommercial | commercial | β | β | 11,930 | 4,908 |
| Mixedresidential | residential | 2.5 | 2.0 | 7,031 | 11,753 |
| Hotcommercial | commercial | β | β | 28,295 | 948 |
| Hotresidential | residential | 2.5 | 3.0 | 21,171 | 1,494 |
Part-load test points (20 values)
- h__h1_min_cap_power_rated
- 3790 W
- h__h2_ext_cap_power_rated
- 15850 W
- c__t1_half_cap_power_rated
- 8380 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 8140 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 16910 W
- h__h2_ext_cap_heat_cap_rated
- 53990 W
- h__h1_half_cap_heat_cap_rated
- 39200 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 3280 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 36400 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 19910 W
Australian GEMS registration details
- Registration number
- AAC7686
- GEMS registration id
- 155707
- Status
- approved, available (self-reported)
- Registration expires
- 6 August 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2020
- Product class
- Class 27