c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
3,969 kWh
1,554 cooling + 2,415 heating
Estimated running cost
$1,270 / year
$106 / month Β· $12,701 over 10 years
Capacity
18 kW cooling
20 kW heating

Only 4 comparable registrations in this cohort, so no percentile is shown.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 24% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Smart User SM4OU-D200MK running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,630$2,442$24,416
Mixed zone 3,969$1,270$12,701
Hot zone 4,877$1,561$15,606

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Smart User SM4OU-D200MK

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Spt AM180C-620.7 kW heating18 kW cooling3,956 kWh/yr3.5$1,266
Midea MULMI0618B20.5 kW heating18 kW cooling4,020 kWh/yr3.5$1,286
Kaden KM6020 kW heating17.5 kW cooling3,977 kWh/yr3$1,273
Carrier 38QUM190D8S621.5 kW heating19 kW cooling4,127 kWh/yr3.5$1,321
Midea MULMI0619C21.5 kW heating19 kW cooling4,127 kWh/yr3.5$1,321

Compare SM4OU-D200MK with another model

Smart User SM4OU-D200MK specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
18.00 kW
Cooling power input
4.97 kW
Rated heating capacity (7 Β°C)
20.00 kW
Heating power input
5.06 kW
EER, full load (tested)
3.96
COP, full load (tested)
4.18
Rated AEER
3.58
Rated ACOP
3.91
Standby power (PIA)
15.5 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
51 dB(A)
Outdoor sound power
62.8 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Smart User SM4OU-D200MK zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,1132,073
Coldresidential3.02.09836,647
Mixedcommercial––2,6791,059
Mixedresidential3.03.01,5542,415
Hotcommercial––6,017230
Hotresidential3.53.54,520357
Part-load test points (20 values)
h__h2_ext_cap_power_rated
5950 W
c__t1_half_cap_power_rated
1650 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1700 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
17800 W
h__h1_half_cap_heat_cap_rated
9800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
4542.58 W
c__low_temp_half_cap_power_rated
1508.1000000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
9000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
19386 W
c__low_temp_half_cap_cooling_cap_rated
9693 W

Australian GEMS registration details

Registration number
AAC8129
GEMS registration id
159867
Status
approved, available (self-reported)
Registration expires
21 March 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.