c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
348 kWh
117 cooling + 231 heating
Estimated running cost
$111 / year
$9 / month Β· $1,114 over 10 years
Capacity
1.8 kW cooling
1.8 kW heating

17% less electricity than the median of 61 comparable 2 kW reverse cycle split system registrations (422 kWh a year) in the mixed zone. Uses less than 98% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 97% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TCL TAC-06CHSD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 632$202$2,022
Mixed zone 348$111$1,114
Hot zone 343$110$1,098

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the TCL TAC-06CHSD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Maxa LZL17 ODU / LZL17 IDU1.8 kW heating1.8 kW cooling354 kWh/yr3.5$113

Other TCL models of similar capacity

ModelStarsEst. cost / yrCompare
TCL TAC-06CHSD/VFIH1.8 kW heating1.8 kW cooling354 kWh/yr3.5$113
TCL TAC-06CHSD/VEIH1.8 kW heating1.8 kW cooling354 kWh/yr3.5$113

Compare TAC-06CHSD/VFIH with another model

TCL TAC-06CHSD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
1.78 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
1.82 kW
Heating power input
–
EER, full load (tested)
4.79
COP, full load (tested)
4.92
Rated AEER
4.47
Rated ACOP
4.82
Standby power (PIA)
3.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
48.8 dB(A)
Outdoor sound power
63.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TAC-06CHSD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––21193
Coldresidential4.02.577555
Mixedcommercial––96111
Mixedresidential4.02.5117231
Hotcommercial––26629
Hotresidential6.03.030043
Part-load test points (18 values)
h__h2_ext_cap_power_rated
860 W
c__t1_half_cap_power_rated
250 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
196 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2800 W
h__h1_half_cap_heat_cap_rated
957 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
125 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
970 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
980 W

Other model numbers on registration AAC8641

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC8641
GEMS registration id
–
Status
approved
Registration expires
10 March 2030
Registered for sale in
Australia, New Zealand
Family
TAC-06CHSD series
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
8