c/kWh
Energy rating (cooling)
0
Annual electricity use
664 kWh
Estimated running cost
$212 / year
$18 / month Β· $2,125 over 10 years
Capacity
2.1 kW cooling

1% more electricity than the median of 40 comparable 2 kW cooling only portable registrations (657 kWh a year) in the mixed zone. Uses less than 25% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 87% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TCL TAC-07CPB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 431$138$1,379
Mixed zone 664$212$2,125
Hot zone 1,775$568$5,680

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Stirling PA19W12 kW cooling630 kWh/yr0$202
Onix ON-20KWPA22 kW cooling630 kWh/yr0$202
Midea MPPA20C2 kW cooling630 kWh/yr0$202
Onix ON-20KWPAW2 kW cooling630 kWh/yr0$202
Devanti PAC-B-7000-WH2 kW cooling630 kWh/yr0$202

Air conditioners similar to the TCL TAC-07CPB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Devanti PAC-A-14K-NEW-WH2.1 kW cooling664 kWh/yr0$212
Alfordson A-PAC-7-WAVE2.1 kW cooling655 kWh/yr0$210
Carson OL-A016AA20N22.1 kW cooling655 kWh/yr0$210
Alfordson A-PAC-72.1 kW cooling655 kWh/yr0$210
Sheffield PL6192.1 kW cooling655 kWh/yr0$210
Ausclimate Ausclimate 2.05kW PAC2 kW cooling655 kWh/yr0$210
TECO TPO20C**AO2 kW cooling655 kWh/yr0$210
Ausclimate ACPAC205CB2 kW cooling655 kWh/yr0$210

Compare TAC-07CPB/SL8 with another model

TCL TAC-07CPB specifications

Type
Cooling only
Configuration
Portable
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.06 kW
Cooling power input
0.79 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
2.62
COP, full load (tested)
–
Rated AEER
2.60
Rated ACOP
–
Standby power (PIA)
–
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
64.2 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TAC-07CPB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldresidential0.0–431–
Mixedresidential0.0–664–
Hotresidential0.0–1,775–

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
TAC-07CPB/SL seriesAAC75320664

Other model numbers on registration AAC7941

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7941
GEMS registration id
158142
Status
approved, available (self-reported)
Registration expires
5 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
TAC-07CPB/SL series
Regulatory standard
[Unitary Single-Duct] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.5:2015
MEPS
2019
Product class
Class 4

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.