c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,695 kWh
974 cooling + 1,721 heating
Estimated running cost
$862 / year
$72 / month Β· $8,624 over 10 years
Capacity
12.5 kW cooling
13.5 kW heating

15% less electricity than the median of 140 comparable 12.5 kW reverse cycle ducted split system registrations (3,178 kWh a year) in the mixed zone. Uses less than 86% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 40% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TECO TDS-TSO125HVFM running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,135$1,643$16,432
Mixed zone 2,695$862$8,624
Hot zone 3,042$973$9,734

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr1.5$538
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr4$707
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819

Air conditioners similar to the TECO TDS-TSO125HVFM

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI4213 kW heating12.5 kW cooling2,587 kWh/yr3.5$828
Mdv C-UV-125N8-QC3W / CDV-125A6N8-QC3W13.5 kW heating12.5 kW cooling2,685 kWh/yr3.5$859
Panasonic U-125PZ4R8 / S-125PE4RN12.5 kW heating12.5 kW cooling2,648 kWh/yr3$847
Kaden KDI42 / KDI4213 kW heating12.5 kW cooling2,587 kWh/yr3.5$828
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Mdv C-UV-125N8-QC3W / CDV-125HN8-QC3W13.5 kW heating12.5 kW cooling2,695 kWh/yr3.5$862
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling2,648 kWh/yr3$847

Compare TDS-TSO125HVFM with another model

TECO TDS-TSO125HVFM specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.70 kW
Rated heating capacity (7 Β°C)
13.50 kW
Heating power input
3.30 kW
EER, full load (tested)
3.56
COP, full load (tested)
3.98
Rated AEER
3.35
Rated ACOP
4.05
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TECO TDS-TSO125HVFM zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5801,438
Coldresidential4.02.06104,525
Mixedcommercial––1,119760
Mixedresidential3.52.59741,721
Hotcommercial––2,975166
Hotresidential4.03.02,783259
Part-load test points (25 values)
c__t1_min_cap_power_rated
900 W
h__h1_min_cap_power_rated
570 W
h__h2_ext_cap_power_rated
5050 W
c__t1_half_cap_power_rated
1580 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1300 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2750 W
h__h2_ext_cap_heat_cap_rated
14100 W
h__h1_half_cap_heat_cap_rated
6450 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
530 W
c__t1_min_cap_cooling_cap_rated
3200 W
c__low_temp_full_cap_power_rated
3381.8 W
c__low_temp_half_cap_power_rated
965 W
c__t1_half_cap_cooling_cap_rated
6400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3750 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6200 W

Australian GEMS registration details

Registration number
AAC7263
GEMS registration id
152450
Status
approved, available (self-reported)
Registration expires
15 February 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.