Australia Β· costs in AUD

Reverse cycle split system air conditioner
TECO TDS-TSO125HVSWDG Air Conditioner
TECO TDS-TSO125HVSWDG is a 12.5 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8387).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,751 kWh
- 959 cooling + 1,792 heating
- Estimated running cost
- $880 / year
- $73 / month Β· $8,803 over 10 years
- Capacity
- 12.5 kW cooling
- 14 kW heating
13% less electricity than the median of 140 comparable 12.5 kW reverse cycle ducted split system registrations (3,178 kWh a year) in the mixed zone. Uses less than 82% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
TECO TDS-TSO125HVSWDG running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,827 | $1,865 | $18,646 |
| Mixed zone | 2,751 | $880 | $8,803 |
| Hot zone | 3,168 | $1,014 | $10,138 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr | 1.5 | $538 | |
| Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr | 4 | $707 | |
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr | 5 | $799 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr | 3.5 | $818 | |
| Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr | 3.5 | $819 |
Air conditioners similar to the TECO TDS-TSO125HVSWDG
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KDI4213 kW heating12.5 kW cooling2,587 kWh/yr | 3.5 | $828 | |
| Mdv C-UV-125N8-QC3W / CDV-125A6N8-QC3W13.5 kW heating12.5 kW cooling2,685 kWh/yr | 3.5 | $859 | |
| Panasonic U-125PZ4R8 / S-125PE4RN12.5 kW heating12.5 kW cooling2,648 kWh/yr | 3 | $847 | |
| Kaden KDI42 / KDI4213 kW heating12.5 kW cooling2,587 kWh/yr | 3.5 | $828 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr | 3.5 | $818 | |
| Mdv C-UV-125N8-QC3W / CDV-125HN8-QC3W13.5 kW heating12.5 kW cooling2,695 kWh/yr | 3.5 | $862 | |
| Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr | 3.5 | $819 | |
| Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling2,648 kWh/yr | 3 | $847 |
Compare TDS-TSO125HVSWDG with another model
TECO TDS-TSO125HVSWDG specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 12.50 kW
- Cooling power input
- 3.68 kW
- Rated heating capacity (7 Β°C)
- 14.00 kW
- Heating power input
- 3.68 kW
- EER, full load (tested)
- 3.37
- COP, full load (tested)
- 3.74
- Rated AEER
- 3.38
- Rated ACOP
- 3.79
- Standby power (PIA)
- 5.1 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
TECO TDS-TSO125HVSWDG zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 502 | 1,609 |
| Coldresidential | residential | 4.0 | 2.0 | 612 | 5,215 |
| Mixedcommercial | commercial | β | β | 731 | 761 |
| Mixedresidential | residential | 3.5 | 2.5 | 959 | 1,792 |
| Hotcommercial | commercial | β | β | 3,132 | 151 |
| Hotresidential | residential | 4.0 | 3.5 | 2,932 | 236 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 720 W
- h__h1_min_cap_power_rated
- 620 W
- h__h2_ext_cap_power_rated
- 3600 W
- c__t1_half_cap_power_rated
- 1250 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1250 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3200 W
- h__h2_ext_cap_heat_cap_rated
- 10300 W
- h__h1_half_cap_heat_cap_rated
- 7000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 390 W
- c__t1_min_cap_cooling_cap_rated
- 2500 W
- c__low_temp_full_cap_power_rated
- 3363.52 W
- c__low_temp_half_cap_power_rated
- 1142.5 W
- c__t1_half_cap_cooling_cap_rated
- 6250 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 2400 W
- c__low_temp_full_cap_cooling_cap_rated
- 13462.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 6731.25 W
Australian GEMS registration details
- Registration number
- AAC8387
- GEMS registration id
- 156343
- Status
- approved, available (self-reported)
- Registration expires
- 11 August 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.