c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
37,846 kWh
16,583 cooling + 21,263 heating
Estimated running cost
$12,111 / year
$1,009 / month Β· $121,107 over 10 years
Capacity
146 kW cooling
148.6 kW heating

46% more electricity than the median of 54 comparable 80 kW and above reverse cycle ducted packaged registrations (25,969 kWh a year) in the mixed zone. Uses less than 26% of them.

Across all 3,681 air conditioner registrations sold in Australia, it uses less than 0% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Temperzone OPA 1410RLTM4FDPQ running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 66,432$21,258$212,582
Mixed zone 37,846$12,111$121,107
Hot zone 52,217$16,709$167,094

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 146 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Temperzone OPA1370RKTMG-P125.5 kW heating131.6 kW cooling17,279 kWh/yr1.5$5,529
Temperzone OPA1370RLTMFQ-P130.9 kW heating136.7 kW cooling18,423 kWh/yr1.5$5,895
Daikin UAXYA130RY1130 kW heating130 kW cooling18,763 kWh/yr1$6,004
Daikin UAXYA130NY1130 kW heating130 kW cooling18,763 kWh/yr1$6,004
Actron Air PKV1400T134 kW heating135 kW cooling19,152 kWh/yr1$6,129

Air conditioners similar to the Temperzone OPA 1410RLTM4FDPQ

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
APAC P150AHR3SA-146.6 kW heating156.7 kW cooling19,505 kWh/yr1.5$6,242
APAC P150AHR3SA-CBR146.6 kW heating156.7 kW cooling19,505 kWh/yr1.5$6,242
Actron Air PKV1400T134 kW heating135 kW cooling19,152 kWh/yr1$6,129
Daikin UAXYA130RY1130 kW heating130 kW cooling18,763 kWh/yr1$6,004
Daikin UAXYA130NY1130 kW heating130 kW cooling18,763 kWh/yr1$6,004

Other Temperzone models of similar capacity

ModelStarsEst. cost / yrCompare
Temperzone OPA 1410RLTM1FPQ142.1 kW heating140.2 kW cooling44,379 kWh/yr1.5$14,201
Temperzone OPA1370RLTMFQ-P130.9 kW heating136.7 kW cooling18,423 kWh/yr1.5$5,895

Compare OPA 1410RLTM4FDPQ with another model

Temperzone OPA 1410RLTM4FDPQ specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
146.00 kW
Cooling power input
45.10 kW
Rated heating capacity (7 Β°C)
148.60 kW
Heating power input
41.20 kW
EER, full load (tested)
3.22
COP, full load (tested)
3.60
Rated AEER
3.23
Rated ACOP
3.59
Standby power (PIA)
46.0 W
Compressor
Variable speed, Inverter (x4) + staging
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, New Zealand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone OPA 1410RLTM4FDPQ zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––22,94618,201
Coldresidential2.01.510,76355,669
Mixedcommercial––29,4709,659
Mixedresidential2.02.016,58321,263
Hotcommercial––65,3732,025
Hotresidential2.02.549,0213,196
Part-load test points (20 values)
h__h2_ext_cap_power_rated
48600 W
c__t1_half_cap_power_rated
23400 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
17500 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
35400 W
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
Yes
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
139600 W
h__h1_half_cap_heat_cap_rated
77100 W
h__h2_full_cap_heat_cap_rated
120200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
19400 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
77400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
79300 W

Australian GEMS registration details

Registration number
AAC8170
GEMS registration id
160420
Status
approved, available (self-reported)
Registration expires
9 April 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
Test standard
AS/NZS 3823.1.2:2012
MEPS
2020
Product class
Class 24

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.