Australia Β· costs in AUD

Cooling only split system air conditioner, wall hung
Toshiba RAS-24E2ACVG-A/RAS-24E2KCVG-A Air Conditioner
Toshiba RAS-24E2ACVG-A/RAS-24E2KCVG-A is a 6 kW cooling only split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC10248).
- Energy rating (cooling)
- 3.5
- Annual electricity use
- 496 kWh
- Estimated running cost
- $159 / year
- $13 / month Β· $1,587 over 10 years
- Capacity
- 6 kW cooling
11% more electricity than the median of 10 comparable 6 kW cooling only split system registrations (449 kWh a year) in the mixed zone. Uses less than 20% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 94% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Toshiba running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 308 | $99 | $986 |
| Mixed zone | 496 | $159 | $1,587 |
| Hot zone | 1,474 | $472 | $4,717 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-18E2ACVG-A/RAS-18E2KCVG-A5.3 kW cooling393 kWh/yr | 4 | $126 | |
| Daikin RKM60WVMA / FTKM60WVMA6 kW cooling412 kWh/yr | 4.5 | $132 | |
| Daikin RKM60W2VMA / FTKM60W2VMA6 kW cooling415 kWh/yr | 4.5 | $133 | |
| Mitsubishi Electric MUY-GW60VFD2/MSY-GW60VFD2 Series6 kW cooling439 kWh/yr | 4 | $140 | |
| Mitsubishi Electric MUY-GW60VFD/MSY-GW60VFD6 kW cooling439 kWh/yr | 4 | $140 |
Air conditioners similar to the Toshiba
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RKM60W2VMA / FTKM60W2VMA6 kW cooling415 kWh/yr | 4.5 | $133 | |
| Mitsubishi Electric MUY-GW60VFD/MSY-GW60VFD6 kW cooling439 kWh/yr | 4 | $140 | |
| Hitachi RAC-DJ60PCAT/RAK-DJ60PCAT6 kW cooling446 kWh/yr | 4 | $143 | |
| Daikin RKM60WVMA / FTKM60WVMA6 kW cooling412 kWh/yr | 4.5 | $132 | |
| Mitsubishi Electric MUY-GW60VFD2/MSY-GW60VFD2 Series6 kW cooling439 kWh/yr | 4 | $140 |
Other Toshiba models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-18E2ACVG-A/RAS-18E2KCVG-A5.3 kW cooling393 kWh/yr | 4 | $126 |
Compare RAS-24E2ACVG-A/RAS-24E2KCVG-A with another model
Toshiba specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.70 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.52
- COP, full load (tested)
- β
- Rated AEER
- 3.52
- Rated ACOP
- β
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 58 dB(A)
- Outdoor sound power
- 63 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Toshiba zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 673 | β |
| Coldresidential | residential | 3.5 | β | 308 | β |
| Mixedcommercial | commercial | β | β | 861 | β |
| Mixedresidential | residential | 3.5 | β | 496 | β |
| Hotcommercial | commercial | β | β | 1,962 | β |
| Hotresidential | residential | 3.5 | β | 1,474 | β |
Part-load test points (5 values)
- c__t1_half_cap_power_rated
- 530 W
- c__t1_have_min_cap_results
- No
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- No
Australian GEMS registration details
- Registration number
- AAC10248
- GEMS registration id
- 180165
- Status
- approved, available (self-reported)
- Registration expires
- 13 September 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: toshiba-aircon.in.th. How the derived figures are calculated.