c/kWh
Energy rating (cooling)
5.5
Heating: 3
Annual electricity use
701 kWh
209 cooling + 492 heating
Estimated running cost
$224 / year
$19 / month Β· $2,243 over 10 years
Capacity
3.6 kW cooling
4.4 kW heating

1% less electricity than the median of 196 comparable 3.5 kW reverse cycle split system registrations (709 kWh a year) in the mixed zone. Uses less than 53% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 85% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Westinghouse WSD36HWB-I running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,411$452$4,515
Mixed zone 701$224$2,243
Hot zone 679$217$2,173

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 3.6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling590 kWh/yr5.5$189
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling595 kWh/yr5$190
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling597 kWh/yr5.5$191
Comfee CASG-XG35/CASN-XG353.8 kW heating3.5 kW cooling610 kWh/yr5$195
Actron Air WRC-035CS / WRE-035CS3.7 kW heating3.5 kW cooling610 kWh/yr5$195

Air conditioners similar to the Westinghouse WSD36HWB-I

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Spt AW036C-1/AW036E3.9 kW heating3.6 kW cooling613 kWh/yr5.5$196
Toshiba RAV-GM401ATP-A/RAV-GM401KRTP-A4 kW heating3.6 kW cooling913 kWh/yr3$292
Rinnai HONRJX35/HINRJX353.8 kW heating3.5 kW cooling645 kWh/yr5$206
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling597 kWh/yr5.5$191
Kaden KSI124 kW heating3.5 kW cooling687 kWh/yr4.5$220
Aux ASW-H36A4/CAR3DI3.8 kW heating3.5 kW cooling645 kWh/yr5$206
Domain ISR-35Q-OUT/ISR-35Q-IND3.6 kW heating3.5 kW cooling672 kWh/yr4.5$215
Hyundai HYSSSAC35TA3.6 kW heating3.5 kW cooling673 kWh/yr4.5$215

Compare WSD36HWB-I/WSD36HWA-E with another model

Westinghouse WSD36HWB-I specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.60 kW
Cooling power input
0.74 kW
Rated heating capacity (7 Β°C)
4.40 kW
Heating power input
0.95 kW
EER, full load (tested)
4.81
COP, full load (tested)
4.74
Rated AEER
4.86
Rated ACOP
4.58
Standby power (PIA)
1.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
51.3 dB(A)
Outdoor sound power
61.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD36HWB-I zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––57410
Coldresidential5.53.01341,277
Mixedcommercial––213219
Mixedresidential5.53.0209492
Hotcommercial––63846
Hotresidential6.03.560772
Part-load test points (23 values)
c__t1_min_cap_power_rated
310 W
h__h1_min_cap_power_rated
305 W
h__h2_ext_cap_power_rated
1750 W
c__t1_half_cap_power_rated
366 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
391 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1750 W
h__h2_ext_cap_heat_cap_rated
5300 W
h__h1_half_cap_heat_cap_rated
2200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
166 W
c__t1_min_cap_cooling_cap_rated
1419 W
c__low_temp_half_cap_power_rated
235 W
c__t1_half_cap_cooling_cap_rated
1774 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1355 W
c__low_temp_half_cap_cooling_cap_rated
1830 W

Other model numbers on registration AAC7559

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7559
GEMS registration id
154815
Status
approved, available (self-reported)
Registration expires
11 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD36HWA-E/WSD36HWA-I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8