c/kWh
Energy rating (cooling)
4
Heating: 3
Annual electricity use
1,035 kWh
362 cooling + 673 heating
Estimated running cost
$331 / year
$28 / month Β· $3,312 over 10 years
Capacity
5.1 kW cooling
6.1 kW heating

5% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 75% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Westinghouse WSD51HWA-E running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,062$660$6,598
Mixed zone 1,035$331$3,312
Hot zone 1,154$369$3,693

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 5.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr4$268
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr4$271
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr4.5$301
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr4$304
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr5$304

Air conditioners similar to the Westinghouse WSD51HWA-E

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense HAWH18KR5.8 kW heating5.1 kW cooling1,069 kWh/yr4.5$342
Hisense HAWU18KR5.8 kW heating5.1 kW cooling1,069 kWh/yr4.5$342
Samsung Electronics AR18AXHQAWKXSA/AR18AXHQAWKNSA6 kW heating5.1 kW cooling1,097 kWh/yr4$351
Actron Air WRC-050DS / WRE-050DS6 kW heating5 kW cooling1,010 kWh/yr5$323
Midea MFEP50VB-W/MFEP50VB-N6 kW heating5 kW cooling1,010 kWh/yr5$323
Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,022 kWh/yr3$327
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling937 kWh/yr5$300
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling942 kWh/yr5$301

Compare WSD51HWA-E/WSD51HWA-I with another model

Westinghouse WSD51HWA-E specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.10 kW
Cooling power input
1.18 kW
Rated heating capacity (7 Β°C)
6.10 kW
Heating power input
1.30 kW
EER, full load (tested)
4.42
COP, full load (tested)
4.68
Rated AEER
4.31
Rated ACOP
4.68
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
63.7 dB(A)
Outdoor sound power
67.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD51HWA-E zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––393580
Coldresidential4.52.52301,832
Mixedcommercial––552299
Mixedresidential4.03.0362673
Hotcommercial––1,31461
Hotresidential4.54.01,05896
Part-load test points (23 values)
c__t1_min_cap_power_rated
431 W
h__h1_min_cap_power_rated
360 W
h__h2_ext_cap_power_rated
1800 W
c__t1_half_cap_power_rated
540 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
535 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2041 W
h__h2_ext_cap_heat_cap_rated
5800 W
h__h1_half_cap_heat_cap_rated
3085 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
325 W
c__t1_min_cap_cooling_cap_rated
1800 W
c__low_temp_half_cap_power_rated
405 W
c__t1_half_cap_cooling_cap_rated
2460 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2200 W
c__low_temp_half_cap_cooling_cap_rated
2780 W

Other model numbers on registration AAC7553

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC7553
GEMS registration id
154739
Status
approved, available (self-reported)
Registration expires
5 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD51HWA-E/WSD51HWA-I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.