Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Westinghouse WSD51HWC-E / WSD51HWC-I Air Conditioner
Westinghouse WSD51HWC-E / WSD51HWC-I is a 5.1 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC10154).
- Energy rating (cooling)
- 5
- Heating: 3
- Annual electricity use
- 1,005 kWh
- 321 cooling + 684 heating
- Estimated running cost
- $322 / year
- $27 / month Β· $3,216 over 10 years
- Capacity
- 5.1 kW cooling
- 6 kW heating
8% less electricity than the median of 240 comparable 5 kW reverse cycle split system registrations (1,093 kWh a year) in the mixed zone. Uses less than 88% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Westinghouse WSD51HWC-E running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,087 | $668 | $6,678 |
| Mixed zone | 1,005 | $322 | $3,216 |
| Hot zone | 1,036 | $332 | $3,315 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 5.1 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling839 kWh/yr | 4 | $268 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling847 kWh/yr | 4 | $271 | |
| Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling942 kWh/yr | 4.5 | $301 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling949 kWh/yr | 5 | $304 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling949 kWh/yr | 4 | $304 |
Air conditioners similar to the Westinghouse WSD51HWC-E
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hisense HAWH18KR5.8 kW heating5.1 kW cooling1,069 kWh/yr | 4.5 | $342 | |
| Hisense HAWU18KR5.8 kW heating5.1 kW cooling1,069 kWh/yr | 4.5 | $342 | |
| Midea MFEP50VB-W/MFEP50VB-N6 kW heating5 kW cooling1,010 kWh/yr | 5 | $323 | |
| Actron Air WRC-050DS / WRE-050DS6 kW heating5 kW cooling1,010 kWh/yr | 5 | $323 | |
| Samsung Electronics AR18AXHQAWKXSA/AR18AXHQAWKNSA6 kW heating5.1 kW cooling1,097 kWh/yr | 4 | $351 | |
| Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,022 kWh/yr | 3 | $327 | |
| Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling937 kWh/yr | 5 | $300 | |
| Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling942 kWh/yr | 5 | $301 |
Compare WSD51HWC-E / WSD51HWC-I with another model
Westinghouse WSD51HWC-E specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 5.08 kW
- Cooling power input
- 1.15 kW
- Rated heating capacity (7 Β°C)
- 6.00 kW
- Heating power input
- 1.46 kW
- EER, full load (tested)
- 4.31
- COP, full load (tested)
- 4.09
- Rated AEER
- 4.41
- Rated ACOP
- 4.11
- Standby power (PIA)
- 1.1 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 62.6 dB(A)
- Outdoor sound power
- 66.6 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Westinghouse WSD51HWC-E zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 302 | 579 |
| Coldresidential | residential | 5.0 | 2.5 | 203 | 1,884 |
| Mixedcommercial | commercial | β | β | 449 | 294 |
| Mixedresidential | residential | 5.0 | 3.0 | 321 | 684 |
| Hotcommercial | commercial | β | β | 1,137 | 58 |
| Hotresidential | residential | 5.5 | 4.0 | 944 | 92 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 312 W
- h__h1_min_cap_power_rated
- 330 W
- h__h2_ext_cap_power_rated
- 1625 W
- c__t1_half_cap_power_rated
- 510 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 525 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1940 W
- h__h2_ext_cap_heat_cap_rated
- 5400 W
- h__h1_half_cap_heat_cap_rated
- 2999.8 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 220 W
- c__t1_min_cap_cooling_cap_rated
- 1350 W
- c__low_temp_half_cap_power_rated
- 360 W
- c__t1_half_cap_cooling_cap_rated
- 2550 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1825 W
- c__low_temp_half_cap_cooling_cap_rated
- 2750 W
Australian GEMS registration details
- Registration number
- AAC10154
- GEMS registration id
- 179471
- Status
- approved, available (self-reported)
- Registration expires
- 14 May 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.