c/kWh
Energy rating (cooling)
2.5
Heating: 1
Annual electricity use
43,088 kWh
5,289 cooling + 37,799 heating
Estimated running cost
$14,219 / year
$1,185 / month Β· $142,190 over 10 years
Capacity
85 kW cooling
86 kW heating

201% more electricity than the median of 14 comparable 80 kW and above reverse cycle ducted split system registrations (14,339 kWh a year) in the cold zone. Uses less than 21% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 2% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air CRV85AT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 43,088$14,219$142,190
Mixed zone 21,698$7,160$71,603
Hot zone 25,195$8,314$83,144

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 85 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
APAC S075OVR3SA/S075IHR3SA-FR72.9 kW heating75.5 kW cooling6,399 kWh/yr1.5$2,112
APAC S075OVR3SA/S075IHR3SA-TR72.9 kW heating75.5 kW cooling6,399 kWh/yr1.5$2,112
Temperzone OSA840RKTBGV/ISD840KBXH-P78.3 kW heating81.3 kW cooling6,969 kWh/yr1.5$2,300
Temperzone OSA950RKTBGV/ISD950KBXH-P90.4 kW heating88.7 kW cooling8,257 kWh/yr1$2,725

Heat pumps similar to the Actron Air CRV85AT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
APAC S085OVR3SA/S085IHR3SA-FR80.8 kW heating84.1 kW cooling7,214 kWh/yr1.5$2,381
APAC S085OVR3SA/S085IHR3SA-TR80.8 kW heating84.1 kW cooling7,214 kWh/yr1.5$2,381
Temperzone OSA950RKTBGV/ISD950KBXH-P90.4 kW heating88.7 kW cooling8,257 kWh/yr1$2,725
Temperzone OSA840RKTBGV/ISD840KBXH-P78.3 kW heating81.3 kW cooling6,969 kWh/yr1.5$2,300

Other Actron Air models of similar capacity

ModelStarsEst. cost / yrCompare
Actron Air CRV850T / EVA850T86 kW heating85 kW cooling50,142 kWh/yr2.5$16,547

Compare CRV85AT / EVA85AT with another model

Actron Air CRV85AT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
85.00 kW
Cooling power input
24.45 kW
Rated heating capacity (7 Β°C)
86.00 kW
Heating power input
22.30 kW
EER, full load (tested)
3.39
COP, full load (tested)
3.80
Rated AEER
3.41
Rated ACOP
3.78
Standby power (PIA)
140.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CRV85AT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––10,35811,777
Coldresidential2.51.05,28937,799
Mixedcommercial––13,4385,694
Mixedresidential2.52.08,19213,506
Hotcommercial––30,1891,280
Hotresidential3.03.023,2541,941
Part-load test points (18 values)
h__h2_ext_cap_power_rated
20140 W
c__t1_half_cap_power_rated
9300 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
8890 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
58750 W
h__h1_half_cap_heat_cap_rated
44000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
7900 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
40100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
44250 W

New Zealand E3 registration details

Registration number
AAC9649
GEMS registration id
175296
Status
approved, available (self-reported)
Registration expires
9 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
Test standard
AS/NZS 3823.1.2:2012
MEPS
2020
Product class
Class 25

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.