New Zealand Β· costs in NZD

Reverse cycle packaged air conditioner
Actron Air PCG260U Heat Pump
Actron Air PCG260U is a 24.7 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9477).
- Energy rating (cooling)
- 1.5
- Heating: 1
- Annual electricity use
- 14,025 kWh
- 2,178 cooling + 11,847 heating
- Estimated running cost
- $4,628 / year
- $386 / month Β· $46,283 over 10 years
- Capacity
- 24.7 kW cooling
- 25.3 kW heating
About the same electricity as the median of 17 comparable 25 kW reverse cycle ducted packaged registrations (14,025 kWh a year) in the cold zone. Uses less than 47% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 9% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air PCG260U running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 14,025 | $4,628 | $46,283 |
| Mixed zone | 7,960 | $2,627 | $26,268 |
| Hot zone | 10,094 | $3,331 | $33,310 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 24.7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air PRV22AT23 kW heating22 kW cooling10,306 kWh/yr | 2.5 | $3,401 | |
| APAC P020AHR3SA-RTR18.9 kW heating22.4 kW cooling11,029 kWh/yr | 1.5 | $3,640 | |
| APAC P020AHR3SA-LBB18.9 kW heating22.4 kW cooling11,029 kWh/yr | 1.5 | $3,640 | |
| Actron Air PRV25AT26 kW heating24.9 kW cooling11,953 kWh/yr | 2.5 | $3,944 | |
| Temperzone OPA242RKTB22 kW heating22.4 kW cooling12,564 kWh/yr | 1.5 | $4,146 |
Heat pumps similar to the Actron Air PCG260U
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA250RLTFPQ26.9 kW heating24.6 kW cooling13,358 kWh/yr | 2.5 | $4,408 | |
| AIRSTAGE RAQ/K/EC/WP/ECO/11024.9 kW heating24.5 kW cooling14,262 kWh/yr | 1.5 | $4,706 | |
| AIRSTAGE RAQ/K/EC/WP/11024.9 kW heating24.5 kW cooling14,262 kWh/yr | 1.5 | $4,706 | |
| APAC P024AHR3SA20.4 kW heating23.4 kW cooling11,785 kWh/yr | 1 | $3,889 | |
| APAC P024AVR3SA-RTR20.4 kW heating23.4 kW cooling11,785 kWh/yr | 1 | $3,889 | |
| Temperzone OPA242RKTB22 kW heating22.4 kW cooling12,564 kWh/yr | 1.5 | $4,146 |
Other Actron Air models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air PRV25AT26 kW heating24.9 kW cooling11,953 kWh/yr | 2.5 | $3,944 | |
| Actron Air PCG233V23.6 kW heating22.9 kW cooling12,680 kWh/yr | 1.5 | $4,184 |
Compare PCG260U with another model
Actron Air PCG260U specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 24.71 kW
- Cooling power input
- 7.25 kW
- Rated heating capacity (7 Β°C)
- 25.25 kW
- Heating power input
- 7.04 kW
- EER, full load (tested)
- 3.27
- COP, full load (tested)
- 3.51
- Rated AEER
- 3.32
- Rated ACOP
- 3.49
- Standby power (PIA)
- 56.0 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air PCG260U zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 4,840 | 4,013 |
| Coldresidential | residential | 1.5 | 1.0 | 2,178 | 11,847 |
| Mixedcommercial | commercial | β | β | 5,949 | 2,198 |
| Mixedresidential | residential | 1.5 | 1.5 | 3,252 | 4,708 |
| Hotcommercial | commercial | β | β | 12,665 | 546 |
| Hotresidential | residential | 1.5 | 1.5 | 9,259 | 835 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 6130.65 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 19476.34 W
- c__low_temp_full_cap_power_rated
- 6392.47 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 25140.08 W
New Zealand E3 registration details
- Registration number
- AAC9477
- GEMS registration id
- 173344
- Status
- approved, available (self-reported)
- Registration expires
- 24 January 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 6
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.