c/kWh
Energy rating (cooling)
1.5
Heating: 0.5
Annual electricity use
9,866 kWh
1,077 cooling + 8,789 heating
Estimated running cost
$3,256 / year
$271 / month Β· $32,558 over 10 years
Capacity
14.7 kW cooling
16 kW heating

28% more electricity than the median of 5 comparable 14 kW reverse cycle ducted packaged registrations (7,724 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 14% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air PRV15AT-T running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 9,866$3,256$32,558
Mixed zone 4,784$1,579$15,787
Hot zone 4,910$1,620$16,203

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air PRV15BT-T15 kW heating14.8 kW cooling6,723 kWh/yr2.5$2,219
AIRSTAGE RAQ/L/EC/WP/1513 kW heating14.9 kW cooling7,686 kWh/yr2$2,536
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling7,720 kWh/yr2.5$2,548
AIRSTAGE RAQ/K/EC/WP/ECO/1513.8 kW heating13.6 kW cooling7,724 kWh/yr1.5$2,549
APAC P015AVR3SA-RTS14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586

Heat pumps similar to the Actron Air PRV15AT-T

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
AIRSTAGE RAQ/L/EC/WP/1513 kW heating14.9 kW cooling7,686 kWh/yr2$2,536
Temperzone VPA160RKTG-P15.8 kW heating15.7 kW cooling8,642 kWh/yr1.5$2,852
AIRSTAGE RAQ/K/EC/WP/*1513.8 kW heating13.6 kW cooling7,724 kWh/yr1.5$2,549
Temperzone OPA161RKTY14.2 kW heating15.9 kW cooling7,937 kWh/yr1.5$2,619
APAC P015AVR3SA-LTT14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
APAC P015AVR3SA-RTS14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586

Other Actron Air models of similar capacity

ModelStarsEst. cost / yrCompare
Actron Air PRV15BT-T15 kW heating14.8 kW cooling6,723 kWh/yr2.5$2,219

Compare PRV15AT-T with another model

Actron Air PRV15AT-T specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.65 kW
Cooling power input
4.37 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.56 kW
EER, full load (tested)
3.27
COP, full load (tested)
3.35
Rated AEER
3.23
Rated ACOP
3.38
Standby power (PIA)
50.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air PRV15AT-T zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,2122,587
Coldresidential1.50.51,0778,789
Mixedcommercial––2,7491,335
Mixedresidential2.01.01,6333,151
Hotcommercial––5,944291
Hotresidential2.52.54,476434
Part-load test points (18 values)
h__h2_ext_cap_power_rated
3747 W
c__t1_half_cap_power_rated
1690 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1640 W
h__h1_have_min_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
9320 W
h__h1_half_cap_heat_cap_rated
7895 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3994.1800000000003 W
c__low_temp_half_cap_power_rated
1544.66 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7350 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
15778.05 W
c__low_temp_half_cap_cooling_cap_rated
7915.95 W

New Zealand E3 registration details

Registration number
AAC6909
GEMS registration id
148031
Status
approved, available (self-reported)
Registration expires
29 August 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 6

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.