c/kWh
Energy rating (cooling)
4.5
Heating: 2
Annual electricity use
3,052 kWh
330 cooling + 2,722 heating
Estimated running cost
$1,007 / year
$84 / month Β· $10,072 over 10 years
Capacity
7.2 kW cooling
8.2 kW heating

3% less electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 66% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 61% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air WRC-072DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,052$1,007$10,072
Mixed zone 1,520$502$5,016
Hot zone 1,701$561$5,613

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Solar Acdc DGWA1-ACDC-24KR27 kW heating6.4 kW cooling2,743 kWh/yr3$905

Heat pumps similar to the Actron Air WRC-072DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar TCHV07T1S/TSHV07T1S7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Bonaire STH072S1AE/STH072S1AI7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Hyundai HYSSSAC72TB7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
TCL TAC-24CHSD/TPH11IH7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Braemar TCHV70T1S/TSHV70T1S7.2 kW heating7.2 kW cooling2,905 kWh/yr3.5$959
Bonaire CRC6911071/CRC69111717.2 kW heating7.2 kW cooling2,905 kWh/yr3.5$959
Hyundai HYSSSAC72T*7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
TCL TAC-24CHSD series7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935

Compare WRC-072DS / WRE-072DS with another model

Actron Air WRC-072DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.20 kW
Cooling power input
1.99 kW
Rated heating capacity (7 Β°C)
8.20 kW
Heating power input
2.08 kW
EER, full load (tested)
3.59
COP, full load (tested)
3.91
Rated AEER
3.61
Rated ACOP
3.94
Standby power (PIA)
0.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.8 dB(A)
Outdoor sound power
67 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air WRC-072DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––466836
Coldresidential4.52.03302,722
Mixedcommercial––725424
Mixedresidential4.03.0531989
Hotcommercial––1,88082
Hotresidential4.53.51,569132
Part-load test points (23 values)
c__t1_min_cap_power_rated
610 W
h__h1_min_cap_power_rated
462 W
h__h2_ext_cap_power_rated
3110 W
c__t1_half_cap_power_rated
780 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
732 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2540 W
h__h2_ext_cap_heat_cap_rated
8160 W
h__h1_half_cap_heat_cap_rated
3960 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
402 W
c__t1_min_cap_cooling_cap_rated
2810 W
c__low_temp_half_cap_power_rated
564 W
c__t1_half_cap_cooling_cap_rated
3540 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2960 W
c__low_temp_half_cap_cooling_cap_rated
3830 W

New Zealand E3 registration details

Registration number
AAC9013
GEMS registration id
170180
Status
approved, available (self-reported)
Registration expires
17 June 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.