c/kWh
Energy rating (cooling)
3.5
Heating: 1
Annual electricity use
5,239 kWh
440 cooling + 4,799 heating
Estimated running cost
$1,729 / year
$144 / month Β· $17,289 over 10 years
Capacity
8.5 kW cooling
9.4 kW heating

45% more electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 37% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air WRC-085CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,239$1,729$17,289
Mixed zone 2,339$772$7,719
Hot zone 2,257$745$7,448

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Kogan KASSSAC80HB8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HC8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling3,328 kWh/yr3.5$1,098
Midea MFXP80WA/MFXP80NA8 kW heating7.6 kW cooling3,333 kWh/yr3.5$1,100
Midea MFXS81WA/MFXS81NA8 kW heating7.6 kW cooling3,333 kWh/yr3.5$1,100

Heat pumps similar to the Actron Air WRC-085CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG WH30SRU-18 / WH30SRN-189 kW heating8.5 kW cooling3,731 kWh/yr3$1,231
Haier 1U85XAGFRA / AS85PFGHRA9.5 kW heating8.5 kW cooling3,660 kWh/yr3.5$1,208
Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling3,477 kWh/yr4$1,147
Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNA1E/I9 kW heating8.5 kW cooling3,550 kWh/yr4$1,172
Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling3,477 kWh/yr4$1,147
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNA1E/I9 kW heating8.5 kW cooling3,550 kWh/yr4$1,172
Braemar WCHV85D1T/WSHV85D1T9 kW heating8.5 kW cooling3,578 kWh/yr4$1,181
LG LS30S0U DX6ALAP/LS30S0N DX6ALAP8.7 kW heating8.6 kW cooling3,679 kWh/yr3$1,214

Compare WRC-085CS / WRE-085CS with another model

Actron Air WRC-085CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.50 kW
Cooling power input
2.40 kW
Rated heating capacity (7 Β°C)
9.45 kW
Heating power input
2.52 kW
EER, full load (tested)
3.49
COP, full load (tested)
3.66
Rated AEER
3.54
Rated ACOP
3.75
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
67 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air WRC-085CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6141,337
Coldresidential3.51.04404,799
Mixedcommercial––984615
Mixedresidential3.51.56941,645
Hotcommercial––2,62099
Hotresidential3.53.52,096161
Part-load test points (23 values)
c__t1_min_cap_power_rated
800 W
h__h1_min_cap_power_rated
480 W
h__h2_ext_cap_power_rated
2270 W
c__t1_half_cap_power_rated
910 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
880 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2559 W
h__h2_ext_cap_heat_cap_rated
5760 W
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
510 W
c__t1_min_cap_cooling_cap_rated
3870 W
c__low_temp_half_cap_power_rated
765 W
c__t1_half_cap_cooling_cap_rated
4250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3350 W
c__low_temp_half_cap_cooling_cap_rated
4500 W

New Zealand E3 registration details

Registration number
AAC9189
GEMS registration id
171656
Status
approved, available (self-reported)
Registration expires
6 August 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.