c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
20,730 kWh
3,209 cooling + 17,521 heating
Estimated running cost
$6,841 / year
$570 / month Β· $68,409 over 10 years
Capacity
36.1 kW cooling
36.2 kW heating

564% more electricity than the median of 30 comparable 35 kW reverse cycle ducted packaged registrations (3,122 kWh a year) in the cold zone. Uses less than 3% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 6% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

AIRSTAGE RAQ running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 20,730$6,841$68,409
Mixed zone 11,865$3,915$39,155
Hot zone 15,452$5,099$50,992

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 36.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
APAC P033AHR3SA-32.9 kW heating34.4 kW cooling2,462 kWh/yr2$812
APAC P033AHR3SA-RRR32.9 kW heating34.4 kW cooling2,462 kWh/yr2$812
Caa VPA030R3AC33.1 kW heating32.1 kW cooling2,638 kWh/yr1.5$871
Temperzone OPA340RKTB30.7 kW heating32.1 kW cooling2,665 kWh/yr1.5$879
Actron Air PCG330U33 kW heating32 kW cooling2,779 kWh/yr1.5$917

Heat pumps similar to the AIRSTAGE RAQ

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
APAC P035AVR3SA-31.5 kW heating36 kW cooling2,497 kWh/yr2$824
APAC P035AHR3SA-RTR31.5 kW heating36 kW cooling2,497 kWh/yr2$824
Caa HPA035R3AD38.1 kW heating36.3 kW cooling2,881 kWh/yr2$951
Temperzone OPA370RKTB35.9 kW heating36.8 kW cooling3,160 kWh/yr1.5$1,043
Temperzone OPA 371RLTP36.2 kW heating37 kW cooling20,669 kWh/yr1.5$6,821
Daikin UAYN350AFY1A34.3 kW heating37.2 kW cooling22,636 kWh/yr1$7,470

Other AIRSTAGE models of similar capacity

ModelStarsEst. cost / yrCompare
AIRSTAGE RAQ/K/EC/WP/ECO/11536.3 kW heating36.2 kW cooling20,561 kWh/yr1.5$6,785
AIRSTAGE RAQ/K/EC/WP/11536.3 kW heating36.2 kW cooling20,561 kWh/yr1.5$6,785

Compare RAQ/K/WP/115 with another model

AIRSTAGE RAQ specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
36.10 kW
Cooling power input
11.50 kW
Rated heating capacity (7 Β°C)
36.20 kW
Heating power input
11.00 kW
EER, full load (tested)
3.20
COP, full load (tested)
3.27
Rated AEER
3.12
Rated ACOP
3.27
Standby power (PIA)
25.5 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

AIRSTAGE RAQ zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7,3935,965
Coldresidential1.51.03,20917,521
Mixedcommercial––9,1143,266
Mixedresidential1.51.04,8507,015
Hotcommercial––19,682726
Hotresidential1.51.014,3051,147
Part-load test points (4 values)
h__h2_full_cap_power_rated
10296 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
31530 W
c__low_temp_have_full_cap_results
No

Other model numbers on registration AAC6482

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6482
GEMS registration id
144358
Status
approved, available (self-reported)
Registration expires
8 February 2027
Registered for sale in
Australia, New Zealand
Family
RAQ/K/WP/* 115
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 6

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.