c/kWh
Energy rating (cooling)
1.5
Heating: 0
Annual electricity use
4,561 kWh
Estimated running cost
$1,505 / year
$125 / month Β· $15,051 over 10 years
Capacity
56.1 kW cooling
54 kW heating

67% less electricity than the median of 24 comparable 50 kW reverse cycle ducted packaged registrations (13,853 kWh a year) in the cold zone. Uses less than 71% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

APAC P055AHR3SA-LTR running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,561$1,505$15,051
Mixed zone 6,902$2,278$22,777
Hot zone 19,004$6,271$62,713

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 56.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Caa HPA055R3AD53.3 kW heating53.4 kW cooling4,198 kWh/yr2$1,385

Heat pumps similar to the APAC P055AHR3SA-LTR

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Caa HPC055R3AD60.9 kW heating56.4 kW cooling4,931 kWh/yr1.5$1,627
Temperzone OPA 551RLTBP48.7 kW heating54.7 kW cooling29,555 kWh/yr1.5$9,753
Temperzone OPA 591RLTBP54.7 kW heating57.7 kW cooling32,591 kWh/yr1.5$10,755
Caa HPA055R3AD53.3 kW heating53.4 kW cooling4,198 kWh/yr2$1,385
Daikin UAYN530AFY1A54.3 kW heating53.4 kW cooling43,024 kWh/yr1$14,198
Daikin UAYN530BFY1A54.3 kW heating53.4 kW cooling43,024 kWh/yr1$14,198
AIRSTAGE RAQ/K/WP/* 22463 kW heating60.5 kW cooling37,630 kWh/yr1$12,418
AIRSTAGE RAQ/K/WP/ECO/22463 kW heating60.5 kW cooling37,630 kWh/yr1$12,418

Compare P055AHR3SA-LTR with another model

APAC P055AHR3SA-LTR specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
56.10 kW
Cooling power input
17.30 kW
Rated heating capacity (7 Β°C)
54.00 kW
Heating power input
15.00 kW
EER, full load (tested)
3.10
COP, full load (tested)
3.44
Rated AEER
3.12
Rated ACOP
3.44
Standby power (PIA)
200.0 W
Compressor
Variable speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC P055AHR3SA-LTR zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––10,012–
Coldresidential1.50.04,561–
Mixedcommercial––12,219–
Mixedresidential1.50.06,902–
Hotcommercial––25,798–
Hotresidential2.00.019,004–
Part-load test points (8 values)
c__t1_min_cap_power_rated
8770 W
c__t1_have_min_cap_results
Yes
c__low_temp_min_cap_power_rated
8060 W
c__t1_min_cap_cooling_cap_rated
36150 W
c__low_temp_full_cap_power_rated
15590 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
37840 W
c__low_temp_full_cap_cooling_cap_rated
59890 W

Other model numbers on registration AAC7428

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7428
GEMS registration id
153706
Status
approved, available (self-reported)
Registration expires
16 April 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
P055AHR3SA-
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
Simulation
MEPS
2019
Product class
Class 7

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.