c/kWh
Energy rating (cooling)
2
Heating: 0
Annual electricity use
2,497 kWh
Estimated running cost
$824 / year
$69 / month Β· $8,240 over 10 years
Capacity
36 kW cooling
31.5 kW heating

17% less electricity than the median of 12 comparable 35 kW reverse cycle ducted split system registrations (3,000 kWh a year) in the cold zone. Uses less than 92% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 69% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

APAC S035OVR3SA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,497$824$8,240
Mixed zone 3,796$1,253$12,527
Hot zone 10,526$3,474$34,736

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the APAC S035OVR3SA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone ISD380KBP/OSA380RKTB38.5 kW heating35.9 kW cooling3,073 kWh/yr1.5$1,014
Temperzone OSA380RKTBG/ISD380KB-P35.7 kW heating35.8 kW cooling3,057 kWh/yr1.5$1,009
Actron Air SCA340C / SCA340E35.5 kW heating33.5 kW cooling3,084 kWh/yr1$1,018
Actron Air CRV330T / EVA330T32.5 kW heating33 kW cooling2,928 kWh/yr1.5$966

Other APAC models of similar capacity

ModelStarsEst. cost / yrCompare
APAC S032OVC3SA- / S032IHC3SA-31.1 kW heating32.9 kW cooling2,917 kWh/yr1.5$963
APAC S032OVR3SA- / S032ILR3SA-31.1 kW heating32.9 kW cooling2,917 kWh/yr1.5$963

Compare S035OVR3SA / S035IHR3SA-FR with another model

APAC S035OVR3SA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
36.00 kW
Cooling power input
9.70 kW
Rated heating capacity (7 Β°C)
31.50 kW
Heating power input
8.90 kW
EER, full load (tested)
3.54
COP, full load (tested)
3.36
Rated AEER
3.59
Rated ACOP
3.41
Standby power (PIA)
100.0 W
Compressor
Variable speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC S035OVR3SA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5,522–
Coldresidential2.00.02,497–
Mixedcommercial––6,752–
Mixedresidential2.00.03,796–
Hotcommercial––14,310–
Hotresidential2.50.010,526–
Part-load test points (8 values)
c__t1_min_cap_power_rated
4930 W
c__t1_have_min_cap_results
Yes
c__low_temp_min_cap_power_rated
4530 W
c__t1_min_cap_cooling_cap_rated
23550 W
c__low_temp_full_cap_power_rated
8760 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
24660 W
c__low_temp_full_cap_cooling_cap_rated
38410 W

Other model numbers on registration AAC7446

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7446
GEMS registration id
153719
Status
approved, available (self-reported)
Registration expires
24 April 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
S035OVR3SA / S035I*R3SA-
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
Simulation
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.