c/kWh
Energy rating (cooling)
1
Annual electricity use
5,980 kWh
Estimated running cost
$1,973 / year
$164 / month Β· $19,734 over 10 years
Capacity
63.4 kW cooling

Only 1 comparable registration in this cohort, so no percentile is shown.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 31% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

APAC S064OVC3SA- running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,980$1,973$19,734
Mixed zone 8,941$2,951$29,505
Hot zone 24,919$8,223$82,233

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 63.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
APAC S054OVC3SA-H / S054IHC3SA-F56.9 kW cooling5,116 kWh/yr1$1,688
APAC S054OVC3SA / S054IHC3SA56.9 kW cooling5,116 kWh/yr1$1,688

Heat pumps similar to the APAC S064OVC3SA-

Technically comparable registrations: same configuration and type, capacity within 12%.

No comparable registrations from other brands.

Other APAC models of similar capacity

ModelStarsEst. cost / yrCompare
APAC S054OVC3SA-H / S054IHC3SA-F56.9 kW cooling5,116 kWh/yr1$1,688
APAC S054OVC3SA / S054IHC3SA56.9 kW cooling5,116 kWh/yr1$1,688

Compare S064OVC3SA- / S064IHC3SA- with another model

APAC S064OVC3SA- specifications

Type
Cooling only
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
63.40 kW
Cooling power input
20.30 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.03
COP, full load (tested)
–
Rated AEER
3.02
Rated ACOP
–
Standby power (PIA)
215.0 W
Compressor
Variable speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC S064OVC3SA- zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––13,470–
Coldresidential1.0–5,980–
Mixedcommercial––16,376–
Mixedresidential1.0–8,941–
Hotcommercial––34,118–
Hotresidential1.5–24,919–
Part-load test points (8 values)
c__t1_min_cap_power_rated
10100 W
c__t1_have_min_cap_results
Yes
c__low_temp_min_cap_power_rated
9200 W
c__t1_min_cap_cooling_cap_rated
31700 W
c__low_temp_full_cap_power_rated
18300 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
33500 W
c__low_temp_full_cap_cooling_cap_rated
67100 W

Other model numbers on registration AAC8477

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8477
GEMS registration id
164758
Status
approved, available (self-reported)
Registration expires
3 October 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
S064OVC3SA / S064IHC3SA
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
Simulation
MEPS
2019
Product class
Class 12

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.