APAC S065OVR3SA / S065IHR3SA- Heat Pump
APAC S065OVR3SA / S065IHR3SA- is a 63.5 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7442).
- Energy rating (cooling)
- 1.5
- Heating: 0
- Annual electricity use
- 4,970 kWh
- Estimated running cost
- $1,640 / year
- $137 / month Β· $16,401 over 10 years
- Capacity
- 63.5 kW cooling
- 62.9 kW heating
16% less electricity than the median of 7 comparable 65 kW reverse cycle ducted split system registrations (5,949 kWh a year) in the cold zone. Uses less than 86% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
APAC S065OVR3SA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,970 | $1,640 | $16,401 |
| Mixed zone | 7,546 | $2,490 | $24,902 |
| Hot zone | 20,856 | $6,882 | $68,825 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 63.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC S055OVR3SA / S055IHR3SA-FR54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 | |
| APAC S055OVR3SA / S055IHR3SA-54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 |
Heat pumps similar to the APAC S065OVR3SA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OSA670RKTB/ISD670KB-P62 kW heating63 kW cooling5,598 kWh/yr | 1.5 | $1,847 | |
| Temperzone OSA670RKTB/ISD670KB62.8 kW heating62.9 kW cooling5,793 kWh/yr | 1.5 | $1,912 | |
| Actron Air CAY620T / ELY620T62.3 kW heating61 kW cooling5,949 kWh/yr | 1 | $1,963 | |
| Actron Air CAY620T / EVY620T62.5 kW heating60.8 kW cooling5,989 kWh/yr | 1 | $1,976 |
Other APAC models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC S055OVR3SA / S055IHR3SA-TR54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 | |
| APAC S055OVR3SA / S055IHR3SA-FR54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 |
Compare S065OVR3SA / S065IHR3SA- with another model
APAC S065OVR3SA specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 63.50 kW
- Cooling power input
- 19.20 kW
- Rated heating capacity (7 Β°C)
- 62.90 kW
- Heating power input
- 17.40 kW
- EER, full load (tested)
- 3.17
- COP, full load (tested)
- 3.45
- Rated AEER
- 3.19
- Rated ACOP
- 3.48
- Standby power (PIA)
- 205.0 W
- Compressor
- Variable speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
APAC S065OVR3SA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 10,890 | β |
| Coldresidential | residential | 1.5 | 0.0 | 4,970 | β |
| Mixedcommercial | commercial | β | β | 13,342 | β |
| Mixedresidential | residential | 1.5 | 0.0 | 7,546 | β |
| Hotcommercial | commercial | β | β | 28,269 | β |
| Hotresidential | residential | 2.0 | 0.0 | 20,856 | β |
Part-load test points (8 values)
- c__t1_min_cap_power_rated
- 9690 W
- c__t1_have_min_cap_results
- Yes
- c__low_temp_min_cap_power_rated
- 8840 W
- c__t1_min_cap_cooling_cap_rated
- 40850 W
- c__low_temp_full_cap_power_rated
- 17160 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 42690 W
- c__low_temp_full_cap_cooling_cap_rated
- 67930 W
Other model numbers on registration AAC7442
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7442
- GEMS registration id
- 153603
- Status
- approved, available (self-reported)
- Registration expires
- 24 April 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- S065OVR3SA / S065IHR3SA
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- Simulation
- MEPS
- 2019
- Product class
- Class 12
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.