c/kWh
Energy rating (cooling)
5
Heating: 1.5
Annual electricity use
1,668 kWh
146 cooling + 1,522 heating
Estimated running cost
$550 / year
$46 / month Β· $5,504 over 10 years
Capacity
3.5 kW cooling
4 kW heating

20% more electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 18% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 79% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Aux ASW-H35A4 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,668$550$5,504
Mixed zone 777$256$2,564
Hot zone 735$243$2,426

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Aux ASW-H35A4

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399
Mitsubishi Electric MUZ-AP35VGD2/MSZ-AP35VGKD23.7 kW heating3.5 kW cooling1,219 kWh/yr5$402
Rinnai HONRPX35/HINRPX35M3.8 kW heating3.5 kW cooling1,217 kWh/yr6$402
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Midea MFEZ35VA-W/MFEZ35VA-N3.8 kW heating3.5 kW cooling1,217 kWh/yr6$402
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Mitsubishi Electric MUZ-AP35VG2/MSZ-AP35VG2 Series3.7 kW heating3.5 kW cooling1,219 kWh/yr5$402
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390

Compare ASW-H35A4/FAR3DI with another model

Aux ASW-H35A4 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.50 kW
Cooling power input
0.94 kW
Rated heating capacity (7 Β°C)
4.00 kW
Heating power input
1.08 kW
EER, full load (tested)
3.82
COP, full load (tested)
3.77
Rated AEER
3.69
Rated ACOP
3.68
Standby power (PIA)
2.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
47.8 dB(A)
Outdoor sound power
58.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Aux ASW-H35A4 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––162449
Coldresidential5.01.51461,522
Mixedcommercial––196223
Mixedresidential4.52.5236541
Hotcommercial––44145
Hotresidential5.03.566471
Part-load test points (21 values)
c__t1_min_cap_power_rated
260 W
h__h1_min_cap_power_rated
210 W
c__t1_half_cap_power_rated
400 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
400 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
970 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1150 W
h__h1_half_cap_heat_cap_rated
2000 W
h__h2_full_cap_heat_cap_rated
2940 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
140 W
c__t1_min_cap_cooling_cap_rated
1190 W
c__low_temp_half_cap_power_rated
230 W
c__t1_half_cap_cooling_cap_rated
1750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1080 W
c__low_temp_half_cap_cooling_cap_rated
1720 W

New Zealand E3 registration details

Registration number
AAC10008
GEMS registration id
175779
Status
approved, available (self-reported)
Registration expires
30 March 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: auxcac.cn. How the derived figures are calculated.