c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
2,994 kWh
327 cooling + 2,667 heating
Estimated running cost
$988 / year
$82 / month Β· $9,880 over 10 years
Capacity
7 kW cooling
7.5 kW heating

5% less electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 76% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 62% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Aux ASW-H71A4 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,994$988$9,880
Mixed zone 1,500$495$4,950
Hot zone 1,629$538$5,376

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the Aux ASW-H71A4

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASHSAC72UB8.2 kW heating7 kW cooling3,596 kWh/yr3.5$1,187
Kogan KASHSAC72UC8.2 kW heating7 kW cooling3,596 kWh/yr3.5$1,187
Rinnai HSNRTX707.5 kW heating7 kW cooling2,949 kWh/yr4$973
Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling2,929 kWh/yr4$967
Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling2,949 kWh/yr4$973
Carrier 42QHG070N8PB/38QUH070N8PB7.5 kW heating7 kW cooling2,949 kWh/yr4$973
Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling2,949 kWh/yr4$973
Kaden KSI247.5 kW heating7 kW cooling2,932 kWh/yr4$968

Compare ASW-H71A4/CAR3DI with another model

Aux ASW-H71A4 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.04 kW
Cooling power input
1.85 kW
Rated heating capacity (7 Β°C)
7.50 kW
Heating power input
1.86 kW
EER, full load (tested)
3.86
COP, full load (tested)
3.70
Rated AEER
3.78
Rated ACOP
4.01
Standby power (PIA)
3.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.4 dB(A)
Outdoor sound power
63.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Aux ASW-H71A4 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––366834
Coldresidential4.02.03272,667
Mixedcommercial––673428
Mixedresidential4.02.5522978
Hotcommercial––1,58489
Hotresidential4.53.01,489140
Part-load test points (23 values)
c__t1_min_cap_power_rated
670 W
h__h1_min_cap_power_rated
500 W
h__h2_ext_cap_power_rated
2480 W
c__t1_half_cap_power_rated
830 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
750 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2500 W
h__h2_ext_cap_heat_cap_rated
6800 W
h__h1_half_cap_heat_cap_rated
3600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
440 W
c__t1_min_cap_cooling_cap_rated
2800 W
c__low_temp_half_cap_power_rated
500 W
c__t1_half_cap_cooling_cap_rated
3500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2900 W
c__low_temp_half_cap_cooling_cap_rated
3300 W

New Zealand E3 registration details

Registration number
AAC9636
GEMS registration id
174434
Status
approved, available (self-reported)
Registration expires
3 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9