c/kWh
Energy rating (cooling)
3.5
Annual electricity use
640 kWh
Estimated running cost
$211 / year
$18 / month Β· $2,112 over 10 years
Capacity
12 kW cooling

Only 4 comparable registrations in this cohort, so no percentile is shown.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 94% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Bonaire CRC6940012 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 640$211$2,112
Mixed zone 1,017$336$3,356
Hot zone 2,992$987$9,874

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Bonaire CRC6940012

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air CCA130S / EAA130S12.2 kW cooling934 kWh/yr2$308
Lennox TSA048S41-1/CH33-44/48B-2F-311.4 kW cooling958 kWh/yr1.5$316
Lennox TSA048S41-111.4 kW cooling958 kWh/yr1.5$316
Braemar KCHV140D1B/KACV140D1S12.7 kW cooling1,096 kWh/yr1.5$362
Braemar KCHV125D1B/KACV125D1S11.2 kW cooling958 kWh/yr1.5$316

Compare CRC6940012/CRC6940112 with another model

Bonaire CRC6940012 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.00 kW
Cooling power input
3.30 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.60
COP, full load (tested)
–
Rated AEER
3.63
Rated ACOP
–
Standby power (PIA)
6.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Bonaire CRC6940012 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,394–
Coldresidential3.5–640–
Mixedcommercial––1,771–
Mixedresidential3.0–1,017–
Hotcommercial––3,993–
Hotresidential3.5–2,992–
Part-load test points (9 values)
c__t1_half_cap_power_rated
1100 W
c__t1_have_min_cap_results
No
c__low_temp_full_cap_power_rated
3016.2000000000003 W
c__low_temp_half_cap_power_rated
1005.4000000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
12924 W
c__low_temp_half_cap_cooling_cap_rated
6462 W

New Zealand E3 registration details

Registration number
AAC7838
GEMS registration id
157339
Status
approved, available (self-reported)
Registration expires
21 October 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: sdlark.com. How the derived figures are calculated.