c/kWh
Energy rating (cooling)
3.5
Annual electricity use
733 kWh
Estimated running cost
$242 / year
$20 / month Β· $2,419 over 10 years
Capacity
14 kW cooling

Only 4 comparable registrations in this cohort, so no percentile is shown.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 93% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Bonaire CRC6940014 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 733$242$2,419
Mixed zone 1,192$393$3,934
Hot zone 3,506$1,157$11,570

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Bonaire CRC6940014

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Lennox TSA048S41-3/CH33-44/48B-2F-313.4 kW cooling1,132 kWh/yr1.5$374
Lennox TSA048S4N42M/CH33-44/48B-2F-313.4 kW cooling1,132 kWh/yr1.5$374
Actron Air CCA150S / EAA150S14.8 kW cooling1,148 kWh/yr2$379
Braemar KCHV140D1B/KACV140D1S12.7 kW cooling1,096 kWh/yr1.5$362

Compare CRC6940014/CRC6940114 with another model

Bonaire CRC6940014 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.30 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.29
COP, full load (tested)
–
Rated AEER
3.24
Rated ACOP
–
Standby power (PIA)
6.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Bonaire CRC6940014 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,563–
Coldresidential3.5–733–
Mixedcommercial––2,017–
Mixedresidential3.0–1,192–
Hotcommercial––4,627–
Hotresidential3.5–3,506–
Part-load test points (9 values)
c__t1_half_cap_power_rated
1200 W
c__t1_have_min_cap_results
No
c__low_temp_full_cap_power_rated
3930.2000000000003 W
c__low_temp_half_cap_power_rated
1096.8 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
15078 W
c__low_temp_half_cap_cooling_cap_rated
7539 W

New Zealand E3 registration details

Registration number
AAC7849
GEMS registration id
157543
Status
approved, available (self-reported)
Registration expires
28 October 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: sdlark.com. How the derived figures are calculated.