c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
27,178 kWh
3,918 cooling + 23,260 heating
Estimated running cost
$8,969 / year
$747 / month Β· $89,687 over 10 years
Capacity
51 kW cooling
56.2 kW heating

96% more electricity than the median of 24 comparable 50 kW reverse cycle ducted packaged registrations (13,853 kWh a year) in the cold zone. Uses less than 21% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 5% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar RTHV500D3S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 27,178$8,969$89,687
Mixed zone 14,933$4,928$49,279
Hot zone 19,422$6,409$64,093

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 51 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
APAC P048AHR3SA-LTR45.9 kW heating46.8 kW cooling3,528 kWh/yr2$1,164
APAC P048AHR3SA-RTR45.9 kW heating46.8 kW cooling3,528 kWh/yr2$1,164
Caa VPA045R3AC49.4 kW heating46.1 kW cooling3,718 kWh/yr1.5$1,227
Caa HPA045R3AD50.4 kW heating46.5 kW cooling3,933 kWh/yr1.5$1,298
Actron Air PKY500T51.8 kW heating49.1 kW cooling4,474 kWh/yr1$1,476

Heat pumps similar to the Braemar RTHV500D3S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Gree GK-H15TC(1)/NhA-M(A)56.2 kW heating51 kW cooling27,178 kWh/yr2$8,969
AIRSTAGE RAQ/K/EC/WP/12050.2 kW heating51.2 kW cooling23,748 kWh/yr2$7,837
AIRSTAGE RAQ/K/EC/WP/ECO/12050.2 kW heating51.2 kW cooling23,748 kWh/yr2$7,837
Aggreko RPA-050D-R410A52.8 kW heating51.6 kW cooling4,725 kWh/yr1.5$1,559
Coates RPA-C05052.8 kW heating51.6 kW cooling4,725 kWh/yr1.5$1,559
Temperzone OPA550RKTB52.6 kW heating52 kW cooling4,933 kWh/yr1$1,628
Temperzone OPA550RKTBG-P53.4 kW heating52.9 kW cooling5,006 kWh/yr1$1,652
Actron Air PKY500T51.8 kW heating49.1 kW cooling4,474 kWh/yr1$1,476

Compare RTHV500D3S with another model

Braemar RTHV500D3S specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
51.00 kW
Cooling power input
16.90 kW
Rated heating capacity (7 Β°C)
56.20 kW
Heating power input
15.80 kW
EER, full load (tested)
2.96
COP, full load (tested)
3.55
Rated AEER
3.01
Rated ACOP
3.55
Standby power (PIA)
8.9 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar RTHV500D3S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8,9757,642
Coldresidential2.01.53,91823,260
Mixedcommercial––11,2094,051
Mixedresidential2.01.56,0778,856
Hotcommercial––24,619838
Hotresidential2.02.018,0951,327
Part-load test points (14 values)
c__t1_half_cap_power_rated
7500 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
7200 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
14200 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
28100 W
h__h2_full_cap_heat_cap_rated
46000 W
h__h2_is_capable_extended_load
No
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
25500 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9177
GEMS registration id
171568
Status
approved, available (self-reported)
Registration expires
5 August 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 7

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.