c/kWh
Energy rating (cooling)
4.5
Heating: 3
Annual electricity use
4,365 kWh
534 cooling + 3,831 heating
Estimated running cost
$1,440 / year
$120 / month Β· $14,405 over 10 years
Capacity
12 kW cooling
13.8 kW heating

29% less electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 99% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Brivis AONSR13B1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,365$1,440$14,405
Mixed zone 2,209$729$7,290
Hot zone 3,543$1,169$11,692

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Brivis AONSR13B1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U125S2SP5FA / AD125S2SM7FA14 kW heating12 kW cooling7,120 kWh/yr2$2,350
Samsung Electronics AC120TXAPNG/SA / AC120TNHDKG/SA14 kW heating12 kW cooling5,952 kWh/yr3$1,964
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125HAA214 kW heating12 kW cooling6,455 kWh/yr2$2,130
Samsung Electronics AC120TXAPKG/SA / AC120TNHDKG/SA14 kW heating12 kW cooling5,952 kWh/yr3$1,964
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125HAA Series14 kW heating12 kW cooling6,455 kWh/yr2$2,130
Panasonic U-125PZ4R5 / S-1014PF3E12.1 kW heating12.1 kW cooling5,030 kWh/yr3$1,660
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Mitsubishi Heavy Industries FDCA125VNP-W / FDUA125VH12.1 kW heating12.1 kW cooling6,773 kWh/yr2.5$2,235

Compare AONSR13B1/AINHU13B1 with another model

Brivis AONSR13B1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.00 kW
Cooling power input
3.05 kW
Rated heating capacity (7 Β°C)
13.80 kW
Heating power input
2.80 kW
EER, full load (tested)
3.83
COP, full load (tested)
4.84
Rated AEER
3.88
Rated ACOP
4.86
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Brivis AONSR13B1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1851,168
Coldresidential4.53.05343,831
Mixedcommercial––234592
Mixedresidential4.03.58131,396
Hotcommercial––1,418132
Hotresidential3.05.03,337206
Part-load test points (25 values)
c__t1_min_cap_power_rated
1200 W
h__h1_min_cap_power_rated
610 W
h__h2_ext_cap_power_rated
3400 W
c__t1_half_cap_power_rated
1810 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1150 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4400 W
h__h2_ext_cap_heat_cap_rated
12600 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
520 W
c__t1_min_cap_cooling_cap_rated
3300 W
c__low_temp_full_cap_power_rated
2787.7000000000003 W
c__low_temp_half_cap_power_rated
1050 W
c__t1_half_cap_cooling_cap_rated
5800 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3300 W
c__low_temp_full_cap_cooling_cap_rated
12924 W
c__low_temp_half_cap_cooling_cap_rated
6000 W

New Zealand E3 registration details

Registration number
AAC7118
GEMS registration id
150339
Status
approved, available (self-reported)
Registration expires
25 October 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.