New Zealand Β· costs in NZD

Cooling only packaged air conditioner
Caa VPA090C3AC Heat Pump
Caa VPA090C3AC is a 96.2 kW cooling only ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7594).
- Energy rating (cooling)
- 1.5
- Annual electricity use
- 8,584 kWh
- Estimated running cost
- $2,833 / year
- $236 / month Β· $28,327 over 10 years
- Capacity
- 96.2 kW cooling
Only 4 comparable registrations in this cohort, so no percentile is shown.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 16% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Caa VPA090C3AC running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 8,584 | $2,833 | $28,327 |
| Mixed zone | 13,035 | $4,302 | $43,016 |
| Hot zone | 38,923 | $12,845 | $128,446 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 96.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P092AHC3SA94.6 kW cooling7,652 kWh/yr | 1.5 | $2,525 | |
| APAC P092AHC3SA-L94.6 kW cooling7,652 kWh/yr | 1.5 | $2,525 |
Heat pumps similar to the Caa VPA090C3AC
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC P092AHC3SA94.6 kW cooling7,652 kWh/yr | 1.5 | $2,525 | |
| APAC P092AHC3SA-L94.6 kW cooling7,652 kWh/yr | 1.5 | $2,525 |
Compare VPA090C3AC with another model
Caa VPA090C3AC specifications
- Type
- Cooling only
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 96.24 kW
- Cooling power input
- 31.47 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.12
- COP, full load (tested)
- β
- Rated AEER
- 3.06
- Rated ACOP
- β
- Standby power (PIA)
- 10.0 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Caa VPA090C3AC zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 20,044 | β |
| Coldresidential | residential | 1.5 | β | 8,584 | β |
| Mixedcommercial | commercial | β | β | 24,753 | β |
| Mixedresidential | residential | 1.5 | β | 13,035 | β |
| Hotcommercial | commercial | β | β | 53,678 | β |
| Hotresidential | residential | 1.5 | β | 38,923 | β |
Part-load test points (1 values)
- c__low_temp_have_full_cap_results
- No
New Zealand E3 registration details
- Registration number
- AAC7594
- GEMS registration id
- 153682
- Status
- approved, available (self-reported)
- Registration expires
- 26 June 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2020
- Product class
- Class 24
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.