c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
3,663 kWh
446 cooling + 3,217 heating
Estimated running cost
$1,209 / year
$101 / month Β· $12,088 over 10 years
Capacity
7.1 kW cooling
8 kW heating

17% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 4% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin DRXF71T2VMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,663$1,209$12,088
Mixed zone 1,829$604$6,036
Hot zone 2,220$733$7,326

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the Daikin DRXF71T2VMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U71TPHRA / AS71TPHRA7.5 kW heating7.1 kW cooling2,815 kWh/yr4$929
Kogan KASSSAC71HB7.5 kW heating7.1 kW cooling2,824 kWh/yr4.5$932
Braemar WCHV70D1T/WSHV70D1T7.1 kW heating7.1 kW cooling2,879 kWh/yr3.5$950
Gree GWH24AVEXH-K6DNA1D/O / GWH24AVEXH-K6DNA1D/I7.8 kW heating7.1 kW cooling3,034 kWh/yr3.5$1,001
Kogan KASSSAC71H*7.5 kW heating7.1 kW cooling2,824 kWh/yr4.5$932
Mitsubishi Heavy Industries SRK/DXK_71/24ZRA-W8 kW heating7.1 kW cooling3,062 kWh/yr3.5$1,010
Gree GWH24AVEXH-K6DNA1C/O / GWH24AVEXH-K6DNA1C/I7.8 kW heating7.1 kW cooling2,992 kWh/yr4.5$987
Mitsubishi Heavy Industries DXC24ZRA-W / DXK24ZRA-W8 kW heating7.1 kW cooling3,062 kWh/yr3.5$1,010

Compare DRXF71T2VMA / DTXF71T2VMA with another model

Daikin DRXF71T2VMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
2.19 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
2.41 kW
EER, full load (tested)
3.25
COP, full load (tested)
3.54
Rated AEER
3.22
Rated ACOP
3.30
Standby power (PIA)
4.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
Yes (requires additional part)
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin DRXF71T2VMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9791,004
Coldresidential2.51.54463,217
Mixedcommercial––1,237479
Mixedresidential2.52.07031,126
Hotcommercial––2,76997
Hotresidential2.53.02,067153
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2130 W
c__t1_half_cap_power_rated
780 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
770 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5800 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
2001.66 W
c__low_temp_half_cap_power_rated
712.9200000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7646.7 W
c__low_temp_half_cap_cooling_cap_rated
3823.35 W

New Zealand E3 registration details

Registration number
AAC6966
GEMS registration id
149119
Status
approved, available (self-reported)
Registration expires
7 September 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.