New Zealand Β· costs in NZD

Cooling only split system air conditioner, wall hung
Daikin RKM25Q2VMA / FTKM25Q2VMA Heat Pump
Daikin RKM25Q2VMA / FTKM25Q2VMA is a 2.5 kW cooling only split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7045).
- Energy rating (cooling)
- 5.5
- Annual electricity use
- 95 kWh
- Estimated running cost
- $31 / year
- $3 / month Β· $314 over 10 years
- Capacity
- 2.5 kW cooling
23% less electricity than the median of 17 comparable 2.5 kW cooling only split system registrations (123 kWh a year) in the cold zone. Uses less than 82% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 100% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RKM25Q2VMA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 95 | $31 | $314 |
| Mixed zone | 148 | $49 | $488 |
| Hot zone | 421 | $139 | $1,389 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAC-DJ25PCAT/RAK-DJ25PCAT2.5 kW cooling90 kWh/yr | 6 | $30 |
Heat pumps similar to the Daikin RKM25Q2VMA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAC-DJ25PCAT/RAK-DJ25PCAT2.5 kW cooling90 kWh/yr | 6 | $30 | |
| Mitsubishi Heavy Industries SRC10YTA-W/SRK10YTA-WF2.5 kW cooling98 kWh/yr | 5 | $32 | |
| Mitsubishi Electric MUY-GW25VFD2/MSY-GW25VFD22.5 kW cooling120 kWh/yr | 3.5 | $40 | |
| Toshiba RAS-10E2ACVG-A/RAS-10E2KCVG-A2.5 kW cooling136 kWh/yr | 3.5 | $45 | |
| Mitsubishi Heavy Industries SRC10YSA-W/SRK10YSA-WF12.5 kW cooling112 kWh/yr | 4 | $37 | |
| Fujitsu AOTH09CNCA/ASTH09CNCA2.5 kW cooling107 kWh/yr | 4.5 | $35 | |
| Panasonic CU-U25AKR / CS-U25AKR2.5 kW cooling122 kWh/yr | 3.5 | $40 | |
| Mitsubishi Electric MUY-GW25VFD2/MSY-GW25VFD2 Series2.5 kW cooling120 kWh/yr | 3.5 | $40 |
Compare RKM25Q2VMA / FTKM25Q2VMA with another model
Daikin RKM25Q2VMA specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.50 kW
- Cooling power input
- 0.49 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 5.05
- COP, full load (tested)
- β
- Rated AEER
- 5.02
- Rated ACOP
- β
- Standby power (PIA)
- 2.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 58 dB(A)
- Outdoor sound power
- 59 dB(A)
- Demand response (AS/NZS 4755)
- Yes (requires additional part)
- Dimensions (WΓHΓD)
- 770 Γ 285 Γ 223 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RKM25Q2VMA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 140 | β |
| Coldresidential | residential | 5.5 | β | 95 | β |
| Mixedcommercial | commercial | β | β | 205 | β |
| Mixedresidential | residential | 5.0 | β | 148 | β |
| Hotcommercial | commercial | β | β | 509 | β |
| Hotresidential | residential | 6.0 | β | 421 | β |
Part-load test points (12 values)
- c__t1_min_cap_power_rated
- 160 W
- c__t1_half_cap_power_rated
- 210 W
- c__t1_have_min_cap_results
- Yes
- c__low_temp_min_cap_power_rated
- 110 W
- c__t1_min_cap_cooling_cap_rated
- 800 W
- c__low_temp_full_cap_power_rated
- 447.86 W
- c__low_temp_half_cap_power_rated
- 155 W
- c__t1_half_cap_cooling_cap_rated
- 1250 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 960 W
- c__low_temp_full_cap_cooling_cap_rated
- 2692.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 1350 W
New Zealand E3 registration details
- Registration number
- AAC7045
- GEMS registration id
- 149254
- Status
- approved, available (self-reported)
- Registration expires
- 26 September 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.