c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
18,995 kWh
2,136 cooling + 16,859 heating
Estimated running cost
$6,268 / year
$522 / month Β· $62,684 over 10 years
Capacity
28 kW cooling
32 kW heating

37% more electricity than the median of 26 comparable 25 kW reverse cycle multi-split / vrf registrations (13,829 kWh a year) in the cold zone. Uses less than 4% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 7% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RQCEQ280PY1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 18,995$6,268$62,684
Mixed zone 10,413$3,436$34,363
Hot zone 9,834$3,245$32,452

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 28 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mdv MV8-252WV2RN1E(MA)25.2 kW heating25.2 kW cooling11,529 kWh/yr2$3,805
Midea MV8-252WV2RN1E(MA)25.2 kW heating25.2 kW cooling11,529 kWh/yr2$3,805
Carrier 38VT010188QTSG28 kW heating28 kW cooling12,336 kWh/yr4$4,071
Toshiba MMY-MUP1001HT8P-A31.5 kW heating28 kW cooling12,536 kWh/yr3$4,137
Carrier 38VT010188HTSG31.5 kW heating28 kW cooling12,536 kWh/yr3$4,137

Heat pumps similar to the Daikin RQCEQ280PY1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MV8-280WV2RN1E(MA)28 kW heating28 kW cooling13,222 kWh/yr2$4,363
Carrier 38VT010188QTSG28 kW heating28 kW cooling12,336 kWh/yr4$4,071
Toshiba MMY-MUP1001HT8P-A31.5 kW heating28 kW cooling12,536 kWh/yr3$4,137
Mdv MV8-280WV2RN1E(MA)28 kW heating28 kW cooling13,222 kWh/yr2$4,363
Fujitsu AJY090LELBH28 kW heating28 kW cooling13,430 kWh/yr2$4,432
LG ARUM101LTE631.5 kW heating28 kW cooling12,560 kWh/yr3.5$4,145
Samsung Electronics AM100DXVGGR/SA31.5 kW heating28 kW cooling13,829 kWh/yr3.5$4,564
Carrier 38VT010188HTSG31.5 kW heating28 kW cooling12,536 kWh/yr3$4,137

Compare RQCEQ280PY1 with another model

Daikin RQCEQ280PY1 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
28.00 kW
Cooling power input
7.32 kW
Rated heating capacity (7 Β°C)
32.00 kW
Heating power input
8.26 kW
EER, full load (tested)
4.25
COP, full load (tested)
4.39
Rated AEER
3.60
Rated ACOP
3.67
Standby power (PIA)
138.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
57 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RQCEQ280PY1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,2836,336
Coldresidential1.51.02,13616,859
Mixedcommercial––5,2483,732
Mixedresidential1.51.03,1557,258
Hotcommercial––11,0261,034
Hotresidential2.50.58,3081,526
Part-load test points (20 values)
h__h2_ext_cap_power_rated
14732 W
c__t1_half_cap_power_rated
3227 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
6679 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
34052 W
h__h1_half_cap_heat_cap_rated
16000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
6690.4800000000005 W
c__low_temp_half_cap_power_rated
2949.478 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
14000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
30156 W
c__low_temp_half_cap_cooling_cap_rated
15078 W

New Zealand E3 registration details

Registration number
AAC7503
GEMS registration id
149958
Status
approved, available (self-reported)
Registration expires
15 May 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.