c/kWh
Energy rating (cooling)
1.5
Heating: 0.5
Annual electricity use
52,203 kWh
5,612 cooling + 46,591 heating
Estimated running cost
$17,227 / year
$1,436 / month Β· $172,270 over 10 years
Capacity
71.2 kW cooling
78.4 kW heating

62% more electricity than the median of 25 comparable 65 kW reverse cycle multi-split / vrf registrations (32,140 kWh a year) in the cold zone. Uses less than 12% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 1% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RQCEQ712PY1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 52,203$17,227$172,270
Mixed zone 27,999$9,240$92,397
Hot zone 27,032$8,921$89,206

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 71.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38VT024188QTSG64.5 kW heating64.5 kW cooling3,377 kWh/yr3.5$1,114
Carrier 38VT024188HTSG69 kW heating67 kW cooling3,827 kWh/yr3$1,263
Hitachi RAS-24FSNS77.5 kW heating67 kW cooling4,772 kWh/yr2$1,575
Hitachi RAS-24FSXNS77.5 kW heating67 kW cooling4,772 kWh/yr2$1,575
LG ARUM241LTE674.3 kW heating67.2 kW cooling30,413 kWh/yr3$10,036

Heat pumps similar to the Daikin RQCEQ712PY1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG ARUM260LTE574.3 kW heating72.8 kW cooling42,005 kWh/yr1.5$13,862
Samsung Electronics AM260DXVGGR/SA78.4 kW heating72.8 kW cooling37,372 kWh/yr3$12,333
Samsung Electronics AM260DXVGGH/SA78.4 kW heating72.8 kW cooling37,372 kWh/yr3$12,333
LG ARUM261LTE674.3 kW heating72.8 kW cooling31,524 kWh/yr3$10,403
Carrier 38VT024188HTSG69 kW heating67 kW cooling3,827 kWh/yr3$1,263
Hitachi RAS-24FSNS77.5 kW heating67 kW cooling4,772 kWh/yr2$1,575
Hitachi RAS-24FSXNS77.5 kW heating67 kW cooling4,772 kWh/yr2$1,575

Other Daikin models of similar capacity

ModelStarsEst. cost / yrCompare
Daikin RQCEQ744PY180.8 kW heating74.4 kW cooling54,682 kWh/yr1.5$18,045

Compare RQCEQ712PY1 with another model

Daikin RQCEQ712PY1 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
71.20 kW
Cooling power input
21.87 kW
Rated heating capacity (7 Β°C)
78.40 kW
Heating power input
21.31 kW
EER, full load (tested)
3.45
COP, full load (tested)
3.89
Rated AEER
3.13
Rated ACOP
3.53
Standby power (PIA)
271.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RQCEQ712PY1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––11,54817,360
Coldresidential1.50.55,61246,591
Mixedcommercial––14,29710,048
Mixedresidential1.50.58,46119,538
Hotcommercial––30,7292,632
Hotresidential2.00.523,0973,935
Part-load test points (16 values)
h__h2_ext_cap_power_rated
40173 W
c__t1_half_cap_power_rated
8835 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
18483 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
77115 W
h__h1_half_cap_heat_cap_rated
39200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
35600 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC7521
GEMS registration id
152987
Status
approved, available (self-reported)
Registration expires
21 May 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
Test standard
AS/NZS 3823.1.4:2012
MEPS
2020
Product class
Class 27

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.