New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Daikin RXJ60TVMA / FTXJ60TVMAK Heat Pump
Daikin RXJ60TVMA / FTXJ60TVMAK is a 6 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10091).
- Energy rating (cooling)
- 2.5
- Heating: 2
- Annual electricity use
- 2,872 kWh
- 381 cooling + 2,491 heating
- Estimated running cost
- $948 / year
- $79 / month Β· $9,478 over 10 years
- Capacity
- 6 kW cooling
- 7.2 kW heating
5% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 16% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 63% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RXJ60TVMA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,872 | $948 | $9,478 |
| Mixed zone | 1,552 | $512 | $5,122 |
| Hot zone | 1,910 | $630 | $6,303 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Hyundai HYSSSAC53TB5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| TCL TAC-VX18HSV/UA5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 |
Heat pumps similar to the Daikin RXJ60TVMA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MFEP60VB-W/MFEP60VB-N6.6 kW heating6 kW cooling2,517 kWh/yr | 5 | $831 | |
| Mitsubishi Electric MUZ-AP60VGD2/MSZ-AP60VGD6.8 kW heating6 kW cooling2,490 kWh/yr | 4.5 | $822 | |
| Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling2,517 kWh/yr | 5 | $831 | |
| Hitachi RAC-VJ60PHAT/RAK-VJ60PHAT7 kW heating6 kW cooling2,619 kWh/yr | 4.5 | $864 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 | |
| Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD6.8 kW heating6 kW cooling2,490 kWh/yr | 4.5 | $822 | |
| Toshiba RAS-22ZAVSG-A / RAS-22ZKVSG-A6.9 kW heating6 kW cooling2,602 kWh/yr | 4 | $859 | |
| Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 |
Compare RXJ60TVMA / FTXJ60TVMAK with another model
Daikin RXJ60TVMA specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.83 kW
- Rated heating capacity (7 Β°C)
- 7.20 kW
- Heating power input
- 1.88 kW
- EER, full load (tested)
- 3.30
- COP, full load (tested)
- 3.84
- Rated AEER
- 3.26
- Rated ACOP
- 3.81
- Standby power (PIA)
- 3.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64 dB(A)
- Outdoor sound power
- 61 dB(A)
- Demand response (AS/NZS 4755)
- Yes (requires additional part)
- Dimensions (WΓHΓD)
- 200 Γ 990 Γ 465 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RXJ60TVMA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 845 | 803 |
| Coldresidential | residential | 2.5 | 2.0 | 381 | 2,491 |
| Mixedcommercial | commercial | β | β | 1,065 | 426 |
| Mixedresidential | residential | 2.5 | 2.5 | 599 | 953 |
| Hotcommercial | commercial | β | β | 2,377 | 90 |
| Hotresidential | residential | 2.5 | 3.0 | 1,769 | 141 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 2220 W
- c__t1_half_cap_power_rated
- 680 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 730 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 7000 W
- h__h1_half_cap_heat_cap_rated
- 3600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- No
Other model numbers on registration AAC10091
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC10091
- GEMS registration id
- 178503
- Status
- approved, available (self-reported)
- Registration expires
- 27 April 2031
- Registered for sale in
- Australia, New Zealand
- Family
- RXJ60TVMA / FTXJ60TVMA*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.