New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Daikin RXM20AVMA / FTXM20AVMA Heat Pump
Daikin RXM20AVMA / FTXM20AVMA is a 2.2 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10030).
- Energy rating (cooling)
- 6
- Heating: 3.5
- Annual electricity use
- 725 kWh
- 79 cooling + 646 heating
- Estimated running cost
- $239 / year
- $20 / month Β· $2,393 over 10 years
- Capacity
- 2.2 kW cooling
- 2.7 kW heating
12% less electricity than the median of 63 comparable 2 kW reverse cycle split system registrations (829 kWh a year) in the cold zone. Uses less than 86% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 93% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RXM20AVMA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 725 | $239 | $2,393 |
| Mixed zone | 380 | $125 | $1,254 |
| Hot zone | 396 | $131 | $1,307 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps similar to the Daikin RXM20AVMA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hyundai HYSSSAC21TC2.1 kW heating2.1 kW cooling749 kWh/yr | 3.5 | $247 | |
| TCL TAC-08CHSD/TPH11ITU2.1 kW heating2.1 kW cooling749 kWh/yr | 3.5 | $247 | |
| Midea MFEF20VA-W/MFEF20VA-N2.5 kW heating2.1 kW cooling750 kWh/yr | 5.5 | $248 | |
| Hyundai HYSSSAC21TD2.1 kW heating2.1 kW cooling749 kWh/yr | 3.5 | $247 | |
| Carrier 38QUH020N8L/42QCE020N8F2.5 kW heating2.1 kW cooling750 kWh/yr | 5.5 | $248 | |
| TCL TAC-08CHSD/*ITU2.1 kW heating2.1 kW cooling749 kWh/yr | 3.5 | $247 |
Other Daikin models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM20W2VMA / FTXM20W2VMA2.7 kW heating2.2 kW cooling829 kWh/yr | 5 | $274 | |
| Daikin RXM20W1VMA / FTXM20W1VMA2.7 kW heating2.2 kW cooling829 kWh/yr | 5 | $274 |
Compare RXM20AVMA / FTXM20AVMA with another model
Daikin RXM20AVMA specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.20 kW
- Cooling power input
- 0.41 kW
- Rated heating capacity (7 Β°C)
- 2.70 kW
- Heating power input
- 0.45 kW
- EER, full load (tested)
- 5.62
- COP, full load (tested)
- 5.72
- Rated AEER
- 5.25
- Rated ACOP
- 5.95
- Standby power (PIA)
- 1.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 55 dB(A)
- Outdoor sound power
- 58 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RXM20AVMA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 123 | 216 |
| Coldresidential | residential | 6.0 | 3.5 | 79 | 646 |
| Mixedcommercial | commercial | β | β | 180 | 118 |
| Mixedresidential | residential | 5.5 | 4.0 | 125 | 255 |
| Hotcommercial | commercial | β | β | 430 | 26 |
| Hotresidential | residential | 6.5 | 4.5 | 356 | 40 |
Part-load test points (20 values)
- h__h1_min_cap_power_rated
- 160 W
- h__h2_ext_cap_power_rated
- 1100 W
- c__t1_half_cap_power_rated
- 185 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 205 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1000 W
- h__h2_ext_cap_heat_cap_rated
- 3700 W
- h__h1_half_cap_heat_cap_rated
- 1350 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 130 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 1100 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 1185 W
New Zealand E3 registration details
- Registration number
- AAC10030
- GEMS registration id
- 178224
- Status
- approved, available (self-reported)
- Registration expires
- 6 April 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.