New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, floor mounted
Daikin RXM35R5V1B Heat Pump
Daikin RXM35R5V1B is a 3.4 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration ZAC0765).
- Energy rating (cooling)
- 3.5
- Heating: 2
- Annual electricity use
- 1,822 kWh
- 164 cooling + 1,658 heating
- Estimated running cost
- $601 / year
- $50 / month Β· $6,013 over 10 years
- Capacity
- 3.4 kW cooling
- 4.5 kW heating
31% more electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 9% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RXM35R5V1B running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,822 | $601 | $6,013 |
| Mixed zone | 845 | $279 | $2,789 |
| Hot zone | 786 | $259 | $2,594 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 3.4 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr | 5.5 | $378 | |
| Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr | 5.5 | $378 | |
| Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr | 6 | $390 | |
| Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr | 5 | $398 | |
| Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr | 5 | $399 |
Heat pumps similar to the Daikin RXM35R5V1B
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG WS12TWU / WS12TWN4 kW heating3.4 kW cooling1,632 kWh/yr | 4 | $539 | |
| Mitsubishi Electric MUZ-GS35VFD2/MSZ-GS35VFD2 Series3.7 kW heating3.4 kW cooling1,433 kWh/yr | 3 | $473 | |
| Mitsubishi Electric MUZ-GS35VFD/MSZ-GS35VFD23.7 kW heating3.4 kW cooling1,433 kWh/yr | 3 | $473 | |
| Fujitsu AOTH12KNCA/ASTH12KNCA4 kW heating3.4 kW cooling1,660 kWh/yr | 4 | $548 | |
| Braemar WCHV35D1T/WSHV35D1T3.7 kW heating3.5 kW cooling1,450 kWh/yr | 4 | $479 | |
| Samsung Electronics AR40H12C1AMX / AR40H12C1AMN4 kW heating3.5 kW cooling1,423 kWh/yr | 5 | $470 | |
| Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr | 5 | $399 | |
| Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr | 6 | $390 |
Compare RXM35R5V1B with another model
Daikin RXM35R5V1B specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Floor mounted
- Rated cooling capacity (35 Β°C)
- 3.40 kW
- Cooling power input
- 0.85 kW
- Rated heating capacity (7 Β°C)
- 4.50 kW
- Heating power input
- 1.15 kW
- EER, full load (tested)
- 4.10
- COP, full load (tested)
- 3.97
- Rated AEER
- 3.93
- Rated ACOP
- 3.84
- Standby power (PIA)
- 5.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 53 dB(A)
- Outdoor sound power
- 61 dB(A)
- Demand response (AS/NZS 4755)
- No
- Dimensions (WΓHΓD)
- 750 Γ 600 Γ 238 mm
- Country of manufacture
- Czechia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RXM35R5V1B zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 186 | 509 |
| Coldresidential | residential | 3.5 | 2.0 | 164 | 1,658 |
| Mixedcommercial | commercial | β | β | 314 | 259 |
| Mixedresidential | residential | 3.5 | 2.5 | 255 | 590 |
| Hotcommercial | commercial | β | β | 775 | 58 |
| Hotresidential | residential | 4.5 | 3.0 | 697 | 89 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 1210 W
- c__t1_half_cap_power_rated
- 420 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 415 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 3510 W
- h__h1_half_cap_heat_cap_rated
- 2250 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 260 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 1700 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 1831 W
Other model numbers on registration ZAC0765
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- ZAC0765
- GEMS registration id
- 143292
- Status
- approved, available (self-reported)
- Registration expires
- n/a (NZ registration)
- Registered for sale in
- New Zealand
- Family
- RXM35R5V1B
- Regulatory standard
- [SEER Non Multi-Split <=65kW] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.co.nz. How the derived figures are calculated.