c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
2,471 kWh
258 cooling + 2,213 heating
Estimated running cost
$815 / year
$68 / month Β· $8,154 over 10 years
Capacity
6 kW cooling
7.2 kW heating

9% less electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 83% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 69% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RXM60W2VMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,471$815$8,154
Mixed zone 1,218$402$4,019
Hot zone 1,328$438$4,382

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/UA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53TB5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Heat pumps similar to the Daikin RXM60W2VMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD6.8 kW heating6 kW cooling2,490 kWh/yr4.5$822
Toshiba RAS-22ZAVSG-A / RAS-22ZKVSG-A6.9 kW heating6 kW cooling2,602 kWh/yr4$859
Midea MFEP60VB-W/MFEP60VB-N6.6 kW heating6 kW cooling2,517 kWh/yr5$831
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling2,517 kWh/yr5$831
Hitachi RAC-VJ60PHAT/RAK-VJ60PHAT7 kW heating6 kW cooling2,619 kWh/yr4.5$864
Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD26.8 kW heating6 kW cooling2,490 kWh/yr4.5$822
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Compare RXM60W2VMA / FTXM60W2VMA with another model

Daikin RXM60W2VMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
6.00 kW
Cooling power input
1.48 kW
Rated heating capacity (7 Β°C)
7.20 kW
Heating power input
1.61 kW
EER, full load (tested)
4.10
COP, full load (tested)
4.57
Rated AEER
4.04
Rated ACOP
4.45
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64 dB(A)
Outdoor sound power
61 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RXM60W2VMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––478696
Coldresidential4.52.52582,213
Mixedcommercial––655355
Mixedresidential4.53.0415803
Hotcommercial––1,53573
Hotresidential4.54.01,213115
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1980 W
c__t1_half_cap_power_rated
510 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
600 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6500 W
h__h1_half_cap_heat_cap_rated
3600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1352.72 W
c__low_temp_half_cap_power_rated
405 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
6462 W
c__low_temp_half_cap_cooling_cap_rated
3231 W

New Zealand E3 registration details

Registration number
AAC6756
GEMS registration id
147057
Status
approved, available (self-reported)
Registration expires
30 May 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.