c/kWh
Energy rating (cooling)
4
Heating: 3
Annual electricity use
3,795 kWh
450 cooling + 3,345 heating
Estimated running cost
$1,252 / year
$104 / month Β· $12,524 over 10 years
Capacity
10 kW cooling
12 kW heating

15% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 84% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RZAV100F2V1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,795$1,252$12,524
Mixed zone 1,975$652$6,518
Hot zone 2,188$722$7,220

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Kogan KASSSAC90HD9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HB9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210

Heat pumps similar to the Daikin RZAV100F2V1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Toshiba RAV-GP1101ATP-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling4,466 kWh/yr3.5$1,474
Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling4,455 kWh/yr4$1,470
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Fujitsu AOTA36LCTL/AUTA36LCLU11.2 kW heating10 kW cooling4,518 kWh/yr3$1,491
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling4,244 kWh/yr3$1,401
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114

Compare RZAV100F2V1 / FCA100CVMA with another model

Daikin RZAV100F2V1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.38 kW
Rated heating capacity (7 Β°C)
12.00 kW
Heating power input
2.50 kW
EER, full load (tested)
4.09
COP, full load (tested)
4.72
Rated AEER
4.12
Rated ACOP
4.72
Standby power (PIA)
14.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61 dB(A)
Outdoor sound power
68 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV100F2V1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7511,065
Coldresidential4.03.04503,345
Mixedcommercial––1,031564
Mixedresidential4.03.57051,270
Hotcommercial––2,458134
Hotresidential4.54.51,984204
Part-load test points (25 values)
c__t1_min_cap_power_rated
478 W
h__h1_min_cap_power_rated
561 W
h__h2_ext_cap_power_rated
3192 W
c__t1_half_cap_power_rated
883 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
998 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3500 W
h__h2_ext_cap_heat_cap_rated
11800 W
h__h1_half_cap_heat_cap_rated
6100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
373 W
c__t1_min_cap_cooling_cap_rated
3000 W
c__low_temp_full_cap_power_rated
2170.75 W
c__low_temp_half_cap_power_rated
657 W
c__t1_half_cap_cooling_cap_rated
5100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3300 W
c__low_temp_full_cap_cooling_cap_rated
10770 W
c__low_temp_half_cap_cooling_cap_rated
5200 W

New Zealand E3 registration details

Registration number
AAC6473
GEMS registration id
144511
Status
approved, available (self-reported)
Registration expires
24 February 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.