c/kWh
Energy rating (cooling)
0
Heating: 2.5
Annual electricity use
789 kWh
330 cooling + 459 heating
Estimated running cost
$260 / year
$22 / month Β· $2,604 over 10 years
Capacity
5 kW cooling
6 kW heating

68% less electricity than the median of 38 comparable 5 kW reverse cycle ducted split system registrations (2,462 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RZAV50CV1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 789$260$2,604
Mixed zone 3,634$1,199$11,992
Hot zone 5,896$1,946$19,457

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH18KBTA/ARTH18KMTAP6 kW heating5 kW cooling0 kWh/yr–$0

Heat pumps similar to the Daikin RZAV50CV1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba RAV-GM561ATP-A1/RAV-GM561DTP-A15.3 kW heating5 kW cooling2,206 kWh/yr3$728
Panasonic CU-Z50UBRA / CS-Z50UD3RAW6.1 kW heating5 kW cooling2,552 kWh/yr3$842
Fujitsu AOTH18KBTA/ARTH18KMTAP6 kW heating5 kW cooling0 kWh/yr–$0
Mitsubishi Electric SUZ-M50VAD2-A/PEAD-M50JAA26 kW heating5 kW cooling2,372 kWh/yr2.5$783
Toshiba RAV-GP561ATP-A1/RAV-GM561DTP-A15.6 kW heating5 kW cooling2,032 kWh/yr3$671
Hitachi PAS-2.0UFASNQ1 / PPIM-2.0UFA1NQ6 kW heating5 kW cooling2,440 kWh/yr3$805
Mitsubishi Electric SUZ-M50VAD2-A/PEAD-M50JAAD6 kW heating5 kW cooling2,372 kWh/yr2.5$783
Fujitsu AOTH18KBTA/ARTH18KLLAP6 kW heating5 kW cooling2,518 kWh/yr3$831

Compare RZAV50CV1 / FBA50BAVMA with another model

Daikin RZAV50CV1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
–
EER, full load (tested)
3.95
COP, full load (tested)
4.53
Rated AEER
3.52
Rated ACOP
4.10
Standby power (PIA)
15.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV50CV1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1441,008
Coldresidential0.02.5330459
Mixedcommercial––8052,411
Mixedresidential0.03.05093,125
Hotcommercial––113104
Hotresidential3.03.51,2284,668
Part-load test points (16 values)
h__h2_ext_cap_power_rated
1550 W
c__t1_half_cap_power_rated
510 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
550 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5500 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9826
GEMS registration id
–
Status
approved
Registration expires
2 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.