c/kWh
Energy rating (cooling)
0
Heating: 0
Annual electricity use
3,188 kWh
608 cooling + 2,580 heating
Estimated running cost
$1,052 / year
$88 / month Β· $10,520 over 10 years
Capacity
2.9 kW cooling
2.5 kW heating

18% more electricity than the median of 11 comparable 2.5 kW reverse cycle portable registrations (2,705 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 59% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Dimplex DPRC29ECO-B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,188$1,052$10,520
Mixed zone 2,189$722$7,224
Hot zone 2,774$915$9,154

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
TCL TAC-09CHPB/MW2.6 kW heating2.6 kW cooling2,529 kWh/yr0$835
TCL TAC-09CHPB/MU2.6 kW heating2.6 kW cooling2,529 kWh/yr0$835
Kensington A007C-09CH1.9 kW heating2.6 kW cooling2,567 kWh/yr0$847
Craig&Russell A007H-09CH1.9 kW heating2.6 kW cooling2,567 kWh/yr0$847
Kensington A007C-09CH1.9 kW heating2.6 kW cooling2,567 kWh/yr0$847

Heat pumps similar to the Dimplex DPRC29ECO-B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Sheffield PLA17382.5 kW heating2.9 kW cooling3,188 kWh/yr0$1,052
Sheffield PLA17382.5 kW heating2.9 kW cooling3,188 kWh/yr0$1,052
TCL TAC-09CHPB/MY2.6 kW heating2.6 kW cooling2,529 kWh/yr0$835
Goldair PAC10142 kW heating2.6 kW cooling2,705 kWh/yr0$893
TCL TAC-09CHPB/MW2.6 kW heating2.6 kW cooling2,529 kWh/yr0$835
Click CPAC1609-H2 kW heating2.6 kW cooling2,705 kWh/yr0$893
Goldair GCPAC220 Range2 kW heating2.6 kW cooling2,705 kWh/yr0$893
Midea MPPD33HB2.8 kW heating3.3 kW cooling3,358 kWh/yr0$1,108

Compare DPRC29ECO-B with another model

Dimplex DPRC29ECO-B specifications

Type
Reverse cycle
Configuration
Portable
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.93 kW
Cooling power input
1.11 kW
Rated heating capacity (7 Β°C)
2.49 kW
Heating power input
0.97 kW
EER, full load (tested)
2.64
COP, full load (tested)
2.58
Rated AEER
2.63
Rated ACOP
2.57
Standby power (PIA)
–
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
63.8 dB(A)
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Dimplex DPRC29ECO-B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldresidential0.00.06082,580
Mixedresidential0.00.09371,252
Hotresidential0.00.02,505269

New Zealand E3 registration details

Registration number
ZAC0784
GEMS registration id
149063
Status
approved, available (self-reported)
Registration expires
n/a (NZ registration)
Registered for sale in
New Zealand
Family
–
Regulatory standard
[Unitary Single-Duct] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
Test standard
AS/NZS 3823.1.5:2015
MEPS
2019
Product class
Class 4

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.