c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
9,450 kWh
1,117 cooling + 8,333 heating
Estimated running cost
$3,119 / year
$260 / month Β· $31,185 over 10 years
Capacity
23.4 kW cooling
25.7 kW heating

29% less electricity than the median of 32 comparable 25 kW reverse cycle multi-split / vrf registrations (13,318 kWh a year) in the cold zone. Uses less than 94% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 15% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Econova ECO-ACV9-S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 9,450$3,119$31,185
Mixed zone 4,828$1,593$15,932
Hot zone 5,387$1,778$17,777

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 23.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-8MF3R725 kW heating22.4 kW cooling8,140 kWh/yr4$2,686
Daikin RSUYA8AYM25 kW heating22.4 kW cooling8,492 kWh/yr3$2,802
Mitsubishi Heavy Industries FDC224KXZPE122.4 kW heating22.4 kW cooling8,641 kWh/yr2.5$2,852
Mitsubishi Heavy Industries FDC224KXZME122.4 kW heating22.4 kW cooling8,706 kWh/yr2.5$2,873
Daikin RSUYA9AYM26 kW heating24 kW cooling9,026 kWh/yr3$2,979

Heat pumps similar to the Econova ECO-ACV9-S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai DONSR24Z925 kW heating23.5 kW cooling13,082 kWh/yr2$4,317
Daikin RSUYA9AYM26 kW heating24 kW cooling9,026 kWh/yr3$2,979
Rinnai DONSR24Z3TA26 kW heating24 kW cooling12,908 kWh/yr2.5$4,260
Haier AU08NFKERA22.6 kW heating22.6 kW cooling11,002 kWh/yr1.5$3,631
Mitsubishi Heavy Industries FDC224KXZME122.4 kW heating22.4 kW cooling8,706 kWh/yr2.5$2,873
Daikin RSUYA8AYM25 kW heating22.4 kW cooling8,492 kWh/yr3$2,802
Panasonic U-8MF3R725 kW heating22.4 kW cooling8,140 kWh/yr4$2,686
Mitsubishi Heavy Industries FDC224KXZPE122.4 kW heating22.4 kW cooling8,641 kWh/yr2.5$2,852

Compare ECO-ACV9-S with another model

Econova ECO-ACV9-S specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
23.40 kW
Cooling power input
5.70 kW
Rated heating capacity (7 Β°C)
25.70 kW
Heating power input
6.28 kW
EER, full load (tested)
3.90
COP, full load (tested)
3.90
Rated AEER
4.05
Rated ACOP
4.04
Standby power (PIA)
24.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
75.3 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Econova ECO-ACV9-S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,7632,593
Coldresidential4.02.51,1178,333
Mixedcommercial––2,5291,339
Mixedresidential3.53.01,7483,080
Hotcommercial––5,964298
Hotresidential4.53.54,926461
Part-load test points (20 values)
h__h1_min_cap_power_rated
1640 W
h__h2_ext_cap_power_rated
7100 W
c__t1_half_cap_power_rated
2470 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2420 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
9500 W
h__h2_ext_cap_heat_cap_rated
23100 W
h__h1_half_cap_heat_cap_rated
13000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
1800 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
10580 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
12650 W

New Zealand E3 registration details

Registration number
AAC9759
GEMS registration id
176122
Status
approved, available (self-reported)
Registration expires
14 January 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.